Staxter Field Tester Tngstructionge Model #SFT (6E) Introduction a This Tester takes some getting used to but, in the hands of a skilled operator, it can save many hours of needless assembly and disassembly of faulty starters. Read these Instructions carefully BEFORE attempting to use the Tester. It will save you time and frustration. The STARTER FIELD TESTER works on the principle of a ““gauss-—metor”. All field coils (main & shunt) are energized by a low voltage, line frequency alternating current. The resulting magnetic flux produced at each pole face is detected by four pick-up coils located in the cylindrical aluminum test mandrel. Each pick-up coil drives its own meter through an appropriate circuit. The meter readings are then compared to a “known good” standard. : Some of the characteristics of this tester are as follows… * On a simple starter body (four identical heavy coils) all four meters will read the same (within 5 meter lines). * A bad coil will show a lower than normal reading on its corresponding meter. * A bad coil will also affect its neighbors as follows… — MAGNETICALLY —- Since, in a four pole motor, coils lying directly opposite from one another have the same polarity, they are magnetically “bucking” each other. Therefore, a weak coil (low meter reading) will cause a good coil lying directly opposite to have a HIGHER than normal reeding. — ELECTRICALLY — A shorted coil will offer less resistance and draw higher current than normal. Since several types of electrical hook~ups are used in starter motors (series-— parallel, etc.}, this also increases the current flowing through a “good” adjacent coil connected in SERIES with the shorted coil. A higher than normal reading will then result in the “good” coil. * Four equal readings which are all lower than normal for the particular body being tested indicate a poor connection that is common to all four coils (such as the ground rivet in Chrysler bodies). Also. if all readings seem low, double check your Test Lead connections. We are dealing with very low resistance here 50 Test Lead contact resistance is a big factor. * Two adjacent poles (e.g., top meter & left meter) showing iow readings indicates a poor connection common to one branch in a series-parallel type connection. In this case, the two remaining “good” coils (bottom meter and right meter) will have higher than normal readings due to lack of magnetic “bucking”. * Readings on all four poles should not always be the same. Whon a shunt (fine wire) coil is present, the shunt pole will generally read higher. The best method is to compare tho “pattern” of the test starter against a “known-good” pattern. The procedure for establishing the correct “pattern” will be discussed later. * Shunt coils must he isolated from the heavy coils {at least at one end) so that they may be separately energized by the “shunt” power source. * Characteristics of grounds and internal shorts in main (heavy) coils bear some attention. The main (series type) field coil consists of a few turns of very heavy copper strap. These coils, therefore, have a very low resistance. Consequently if a “small” (high resistance) coil-to-coil connection or a “small” (high resistance) ground fault (to the case) is present in the winding, it will only affect the meter readings to the extent that it draws current away from its intended path through the heavy strap in the coil. For this reason, a “small” ground which might light a 110 volt test light may not be distinguishable on the SFT Tester, You might want to continue testing for grounds with such a light test. Also, don’t stop visual inspection of coils, | insulation and connections for signs of discoloration or other damage. Testing — It is a good idea to start using your SFT by testing at least 10 bodies of the same type preferably a simple Chrysler body with no shunt coil. Testing “one of each kind” will only lead to confusion. Connections — The starter body to be tested is placed over the Test Mandrel and aligned so that each pole shoe faces a sensing head on the mandrel. Connect “COMMON” (Large Black) to starter body (unpainted area). Connect “MAIN” (Large Red) lead to series field input. Connect “SHUNT” test lead to shunt field input (if there is a shunt coil). ¢ Turn on power switch (at right). Pilot will come on. Left hand switch marked “MAIN” controls the SERIES power supply (Large RED Test Clip) used for testing heavy (series) coils. The next switch, marked “SHUNT”, controls the shunt coil power supply (Small RED Test Clip). Large BLACK Test Clip is COMMON to both power supplies. In most cases, series and shunt type coils can be tested either geparately or together. Depress MAIN test switch and note (write down) readings for all four poles. Readings should agree with limits established by testing a group of KNOWN GOOD BODIES as described below. A variation of 2- 1/2 lines either way is acceptable.