1ode ) TECH TIPS Dixie Part Numbers: TBA Applications: 2010 Chevrolet Colorado 2010 GMC Canyon Condition: The operator of the vehicle may complain that the engine intermittently will not crank. Cause: A potential cause for the above condition is an improperly crimped connection in the moulded fuse holder on the positive battery cable. Correction: A voltage drop test should verify if the fuse holder is the cause of the problem, see TSB-001 Voltage Drop Testing for a general guide to perform this test. The manufacturer recommends replacing the fuse holder (manufacturer’s number 19116350) if found to be the problem. REV: 20110506 Courtesy of APRA TSB_1011.docx Dixie Tech Tips are intended for use by professional technicians, and are not for the general public. They are written to inform technicians of conditions that may exist or as a guide to aid in diagnosing and servicing a vehicle. All references to original equipment manufactures, vehicle manufactures and any other Trade Mark names are for the sole purpose of identifying the vehicle and or part that the Tech Tip applies to. This document is property of Dixie Electric Ltd. and is not to be copied or distributed with out written permission.