LEXIE } TECH TIPS Dixie Part Numbers: TBA Applications: 2010 — 2011 MCI D4505 Conditions: The operator of the vehicle may complain of erratic electrical problems including low/dead batteries, hard starting conditions or an engine compartment fire. Cause: A potential cause for the above condition is water contamination on the alternator battery terminal, causing the terminal to corrode and develop a high voltage drop. Correction: Follow the manufacturer’s inspection and repair procedures when applicable. REV: 20120511 Courtesy of Recallcast.com TSB_1053.docx Dixie Tech Tips are intended for use by professional technicians, and are not for the general public. They are written to inform technicians of conditions that may exist or as a guide to aid in diagnosing and servicing a vehicle. All references to original equipment manufactures, vehicle manufactures and any other Trade Mark names are for the sole purpose of identifying the vehicle and or part that the Tech Tip applies to. This document is property of Dixie Electric Ltd. and is not to be copied or distributed with out written permission.