chiwia . & | [| { 8 | anees / TECH TIPS Dixie Part Numbers: S-2095, S-2098, S-80143 Applications: 2001 — 2002 Ford F150 and SuperDuty F Series with either the alternate fuel or liquid propane fuel options. Condition: The vehicle may exhibit some or all of the following conditions: – cranking with out starting when operating in alternate fuel mode (the alternate fuel light will be on) and when in gas mode the vehicle operates – surging when idling and/or surging when at the cruise condition (the alternate fuel light will be on). – repeat starter motor failures. Cause: The potential cause for this could be the following: – acontaminated Compuvalve, – contaminated or faulty Low Flow Injectors, – afaulty Compuvalve system board, – or contaminated fuel that has caused the Low Flow Injectors to stick. Correction: Follow the manufactures procedures for testing the Compuvalve system REV: 20090512 Courtesy of APRA TSB_205.doc Dixie Tech Tips are intended for use by professional technicians, and are not for the general public. They are written to inform technicians of conditions that may exist or as a guide to aid in diagnosing and servicing a vehicle. All references to original equipment manufactures, vehicle manufactures and any other Trade Mark names are for the sole purpose of identifying the vehicle and or part that the Tech Tip applies to. This document is property of Dixie Electric Ltd. and is not to be copied or distributed with out written permission.