chiwia | & | [| { 8 | anees / TECH TIPS Dixie Part Numbers: 405-10105 405-10201 MS-6003 TS-5096 TS-5096B Applications: 1949 — 1955 Massey Hydraulic Table Lift Various other implements Condition: The technician may observe that the relays and wiring harnesses have deteriorated over time to the point that they no longer function nor can they be clearly identified making repairs difficult. Cause: One cause for difficulty in repairing the wiring and relays is age and deterioration. Another reason is the number of ways which the relays have been connected over the years. Correction: Attached are four typical wiring configurations to allow the motor to operate in either direction. Diag ram 1 REV: 20100427 Courtesy of SVA Power Products TSB_501.doc Dixie Tech Tips are intended for use by professional technicians, and are not for the general public. They are written to inform technicians of conditions that may exist or as a guide to aid in diagnosing and servicing a vehicle. All references to original equipment manufactures, vehicle manufactures and any other Trade Mark names are for the sole purpose of identifying the vehicle and or part that the Tech Tip applies to. This document is property of Dixie Electric Ltd. and is not to be copied or distributed with out written permission.