mxIe ) TECH TIPS Dixie Part Numbers: S-8682 TBA Applications: 2007 — 2009 Jaguar XK Condition: The operator of the vehicle may complain of that the engine fails to crank intermittently after shutting the engine off for a short period (10 minutes) and that the remote door unlock had also not functioned. After waiting another 10 minutes everything functions as normal. Cause: A potential cause for the above condition is a software issue between the central junction box and the auxiliary junction box. Correction: The manufacturer has released a software update to resolve the above issue. Follow the manufacturer’s recommended procedures to update the system with patch file 3 or later. REV: 20100618 Courtesy of APRA TSB_8024.doc Dixie Tech Tips are intended for use by professional technicians, and are not for the general public. They are written to inform technicians of conditions that may exist or as a guide to aid in diagnosing and servicing a vehicle. All references to original equipment manufactures, vehicle manufactures and any other Trade Mark names are for the sole purpose of identifying the vehicle and or part that the Tech Tip applies to. This document is property of Dixie Electric Ltd. and is not to be copied or distributed with out written permission.