FAIRBANKS-MORSE MAGNETO DIVISION BELOIT, WISCONSIN INSTRUCTION 3063A SUPERSEDES INSTRUCTION 3063 April 1958 TYPE FM-WG2P87 FLYWHEEL MAGNETO GENERATOR FOR 30 H. P. WESTBEND OUTBOARD MOTOR GENERAL DESCRIPTION Modern ignition systems are designed to provide quick, easy starting and maximum de- pendability of engine operation with minimum adjustment and service. Advanced engineering and rugged construction has made Fairbanks – Morse magnetos performance leaders in the field. Adjustments, when necessary, are sim- ple and shouldbe made inaccordance with these instructions. It is suggested that the magneto be examined only when it is certain that the ig- nition spark is not satisfactory. This condition may be determined by tests easily made in the field, TESTING THE IGNITION SPARK With good spark plugs, properly adjusted, the ignition spark should bridge a short gap in addition to the actual spark plug discharge at the engine. This may be determined with the engine running by holding the end of the ignition cable about 1/16 inches from the spark plug terminal. The usual precautions should be taken to avoid electric shock. The engine should not Tests should not be made while any part of the system is wet. misfire when this is done. SERVICING BREAKER POINTS Before examining the breaker points, it will be necessary to remove the flywheel. This is done by loosening the flywheel nut until it is flush withthe end of the crankshaft. Then strike the nut sharply witha hammer. This will jar the flywheel loose from the crankshaft taper. Remove the nut and lift off the flywheel. Breaker points should be inspected for pit- ting or pyramiding. They should be clean and meet squarely. A small tungsten file or fine stone should be used to resurface the points. Badly worn or pitted points should be replaced. When it is necessary to resurface or replace the breaker points, it will also be necessary to adjust them tothe correct clearance of 0.020 in. after the follower is aligned with the groove machined on top of the cam. This adjustment INSTRUCTION 3063A April 1958 Move the crankshaft until the pointsare fully open. Loosen the contact support locking screws, then insert a screwdriver inthe small triangular depression on the plate and turn it until the correct clear- ance is obtained. Lock the assembly in place by tightening the locking screws; then take a final measurement of the breaker point gap. Repeat this procedure with the other set of points. is made in the following manner: FIELD SERVICE NOT RECOMMENDED The cam felt wicks, when dry orhard, should be replaced by new factory impregnated wicks. Other than this, Fairbanks-Morse mag- netos should not require field lubrication. Coil and condenser replacements are not recom- mended unless the correct testing equipment is available. If facilities are available, test the generator coil for continuity and groundedturns. Replace all coils found lacking in continuity. No further test can be recommended. The gen- erator produces approximately 35 to 40 amperes as measured from the rectifier, and the only regulation is the battery. CAUTION: DO NOT OPERATE THE GEN- ERATOR THROUGH THE RECTIFIER WITHOUT HAVING THE BATTERY CON- NECTED. MAGNETO SERVICE FACILITIES Authorized Fairbanks-Morse magneto ser- vice stations are located throughout the United States and foreign countries. These service stations have been carefully selected by Fair- banks, Morse & Company to insure complete, highly efficient repair service and genuine re- pair parts for owners of Fairbanks-Morse mag – netos. These service stations are especially equipped for magneto repair and are manned by trained personnel. They maintain close contact with the factory service and engineering depart- ments. The station nearest you can be located by referring to Bulletin FM18, latest state. Genuine replacement parts can be obtained Printed in U.S.A File Section – TYPE FM-W Page 2 3063A TYPE FM-WG2P87 FLYWHEEL MAGNETO GENERATOR Instructions from all Authorized Service Stations and should and economical. In addition to voiding the always be insisted on for repairs. The use of manufacturer’s guaranty. spurious parts usually proves less satisfactory it: 62471 B4002 65930 DOO NON ay LE a27e8a 2 SPA OP SOS % SOA ZB Ca Ox 2477 — ees: > ei K€ By Coy A vata’, ) K2473 A2736B H2432A SYX2433 > } Lx2477 we e ie Ee | A2435 U2424 Stator Plate Assembly a asa Ain Gate We iB SY CRP ee ge A Cae a id 1 H2424C Plate, Field Lamination, Coil, Breaker Arm, Point Set and Condenser Avesem Diy go ge de Ses Gig ae 10S16V Field Lamination Screw – #10-24xl”. H2432A Cam SXY2433 Condenser 8S6J Condenser Mounting Screw – #8-32×3/8″‘ A2435 Condenser Mounting Bracket P2437A Contact Set y. dare seh ah SOY Petite 8S6J Contact Set Screws – #8-32×3/8″ ed 6S6N Breaker Arm Terminal Screw – #6-32×3/8′”‘ 6LWl Breaker Arm Terminal Screw Lockwasher G2471 Lead Wire Clip Sade gab aoe te ee 8S6J Lead Wire Clip Screw – #8-32×3/8’! F2473 Grommet – Rubber K2473 Grommet Paes B2476 Coil