ERA Office: Monday – Friday 9:00-5:00 CST

275 W. BROWN ST, UNION, MO 63084

636-584-7400

office@electricalrebuilders.org

ERA Tech Helpline: 636-584-TECH (8324)

FAIRBANKS MORSE ——————————— A_ MAJOR INDUSTRIAL COMPONENT OF ————_————— ee FAIRBANKS WHITNEY GROUND SWITCHES AND TERMINALS MAGNETO and ENGINE ACCESSORIES DIVISION « BELOIT, WISCONSIN MAGNETO GROUND SWITCHES AND TERMINALS The use of primary ground switches or terminals on magneto equipped spark ignition engines is practically universal. Such a prac- tice has resulted in the introduction of many designs of which a few have become standard. L6OI8 ~ K60I8 ec K6OI8- _—— 6NI 6SION_ A2514B B2499A— [10 077 028] H2514 All66 G2457A A2735A A25|4H 6S6N BI355 BIO77 / = 6LWI A60I8 [10 077 032] G2457A 02458 6NI ~~B2735A [10 077 033] FILE SECTION—IMPULSE COUPLINGS, GROUND SWITCHES PRINTED IN U.S.A. It is our recommendation that the terminal or switch be ordered as a complete group. Ar- rangements have been made to pack each switch in a separate container. PRIMARY GROUND TERMINAL Ground Terminal Group – A2514B – Used on FM-J magnetos. Switch is connected by an insulated wire to a control panel away from the magneto. Group consists of (1) E2457A Bush- ing, (1) D2458 – #6 Washer, (1) B2499A Terminal Wire Assembly, (2) K6018 Insulator Washers, (1) L6018 Terminal Insulator, (1) 6S10N – #6-32 x5/8” Screw, (1)6LW2 -#6 Lockwasher and (2) 6N1 – #6 Nuts. PRIMARY GROUND TERMINAL – RADIO SHIELDED MAGNETOS Primary Ground Terminal -A2514H – Used on FM-JE4 and FM-JFE2 magnetos where shielding is required. Group consists of (1) B1077 Cable Ferrule, (1) All166 Terminal Insu- lator, (1) B1355 Ground Strip Guide, (1) G2457A Bushing, (2) D2458 – #6 Washer, (1) H2514 Ground Strip, (1) A2735A Cable Nut, (1) A3969 Cable Terminal, (1) A6018 Insulator Washer, (1) 6S6N – #6-32×3/8″ Screw, (1) #6LW1 – #6 Lockwasher, (1) 6N1 – #6 Nut. PRIMARY GROUND TERMINAL – RADIO SHIELDED MAGNETOS Primary Ground Terminal – A2514J – Used on FM-JVE4B7 magnetos where shielding is re- quired. Groupconsists of (1) Dl1077 Cable Fer- rule, (1) Bl1l66 Terminal Insulator, (1) B1355 Strip Guide, (1) G2457A Bushing, (2) D2458 – #6 Washer, (1) J2514 Ground Strip, (1) B2735A Cable Nut, (1) A3969 Cable Terminal, (1) C6018 Insulator Washer, (1) 6S7N – #6-32×7/16”Screw, (1) 6LW1 – #6 Lockwasher, (1) 6N1 – #6-32 Nut. (eae Bulletin FM347A cur fuera ] Supersedes 347 PR July, 1963 Page 2 347A Cé6é0I8 bere 8NI 8SI4N B2514B 8LWE6E J2499A 10 077 035 B2513 So x A4466 rs tT bt A5974 A CK AX B2514C 10077 036, L6OI8 BS E2514C iY 02514 SKS SOS K6018 ———_. D2458 xx ZZ SS Oe 6LW2 —— 6NI y as ox _— =— — 6SI2N af] \ ie —_—— C60I8A ou i be D2499A E2457A 8LW5 HIB A4466 y C2514 7 Heslac 8NI Ground Switches and Terminals PRIMARY GROUND TERMINAL Ground Terminal Group – B2514B – Used on FM-XV4B70E magnetos. Group consists of (1) K2457A Bushing, (1) J2499A Terminal Wire Assembly, (2) C6018 Insulator Washer, (1) 8S14N – #8-32×7/8′”‘ Screw, (1) 8LW6 – #1208 Lockwasher, (1) 8LW5 – #8 Lockwasher, (3) 8N1 – #8-32 Nut. PRIMARY GROUND SWITCH – TYPE Primary Ground Switch Group – B2514C – Usedon FM, FM-K and FM-Omagnetos. Group consists of (1) B2513 Contact Spring, (1) C2514 Lever, (1) A4466 Terminal Nut, (1) A5974 Screw, (1) 8LW5 – #8 Lockwasher, (1) 8N1 – #8 -32 Nut. PRIMARY GROUND SWITCH – INSULATED LEVER Primary Ground Switch Group – E2514C – Used on FM-J4A30B magnetos. Group consists of (1) E2457A Bushing, ¢1) D2458 – #6 Washer, (1) D2499A Terminal Wire Assembly, (1) D2514 Insulated Lever, (1) K6018 Insulator Washer, (1) L6018 Terminal Insulator, (1) C6018A Insu- lating Block, (1) 6S12N – #6-32×3/4″ Screw, (1) 6LW2 – #6 Lockwasher, (3) 6N1 – #6-32 Nut. PRIMARY GROUND SWITCH – LEVER TYPE Primary Ground Switch – H2514C – Used on FM-XR magnetos. Group consists of (1) H2513 Spring, (1) C2514 Lever, (1) A4466 Nut, (1) C5974 Screw, (1) 8LW5 – #8 Lockwasher, (1) 8N1 – #8-32 Nut. Ground Switches and Terminals Page 3 347A PRIMARY GROUND SWITCH Primary Ground Switch – K2514C. Used on FM-B2B magnetos. Group consists of com- plete switch as shown. PRIMARY GROUND SWITCH INSULATED LEVER Primary Ground Switches – L2514C and N2514C. Used on FM-ZV4B7 and FM-XD1B7 magnetos. Group consists of (1) K2457A Bush- ing, (1) J2499A Terminal Wire Assembly, (1) D2514 Insulated Lever, (2) C6018 Insulator Washer, (1) 8S14N – #8-32×7/8″‘ Screw, (1) 8LW5 – #8 Lockwasher, (3) 8N1 – #8-32 Nut. PRIMARY GROUND SWITCH – PUSH BUTTON Primary Ground Switch – M2514C – Used on FM-ZVE4B7 magnetos. Group consists of (1) V1498 Snap Ring, (1) C2513A Button Spring, (1) A2735A Nut, (1) C4373 Bushing. PRIMARY GROUND SWITCH – PUSH BUTTON Primary Ground Switch – FX2514C – Used on FM-XFE2B7 magnetos. Group consists of (1) V1498 Snap Ring, (1) C2513A Button Spring, (1) S2514 Button, (1) A2735A Nut, (1) C4373 Bushing. PRIMARY GROUND SWITCH – PUSH BUTTON Primary Ground Switch – GX2514C – Used on FM-PE1-2B7E and FM-PEIB7A magnetos. Groups consists of (1) V1498 Snap Ring, (1) C2513A Spring, (1) $2514 Button, (1) E4373 Bushing. cé0ol8 K2457A cé6ol8 8SI4N “BNI J2499A [10 077044) A2735A M2514C ene C2513A C4373 V1498 [lo 077 046] v1498 C4373 A2735A C251

File Type: pdf
File Size: 3 MB
Categories: magnetos