OT-0711 GENERAL DESCRIPTION The OT-0711 package will free run and load test starters; included in this tester is an oscilloscope, D.C. power supply and tachometer circuit. This tester is equipped with a pneumatic vise to facilitate the testing of starters. Three digital meters display power supply voltage, starter loadamps, solenoid amps, and R.P.M. Two built in shelves hold unused plates and a third shelve is for accessories. A preset load reduces the time required to test the starters. AIR REQUIREMENT Connect house air (150 psi maximum) to the 1/4 N.P.T. pipe at the rear of the tester. Adjust the regulator to approximately 40 psi. ELECTRICAL REQUIREMENT 220 volt (208-250) A.C. single phase at 20 amps is required to operate this tester. Connection to the local disconnect box at the rear of the tester should be made by a qualified electrician according to local electrical codes. MECHANICAL SET UP Two different drive gears are supplied with this tester; the OT-1093 Chrysler (28 teeth), the OT-1094 Ford-Delco (32 teeth). The drive gear is held in position by a locking ring accessible through the front of the tester when the mounting plate is off. To remove the gear use snap ring pliers to spread and remove the snap ring, install the re- quired gear. OT-0711 MECHANICAL SET UP (Cont. ) On the base plate in front of the drive gear are eight large holes and four smal] holes ones which are used to locate the pneumatic vise in various positions. The left hand row of hole sets are used for Chrysler starters _and the other are used for Ford or Delco starters. When preparing to test a starter align the pneumatic vise to hold the starter into the tester so that it can be easily removed when the air pressure is released. Select the correct mounting plate (each plate is stamped with a number) using the tooling plate chart. Slide the plate into the brackets with the positioning pin facing outward. Place the starter up against the mounting plate so that one of its nose housing bolt holes align with the positioning pin; close the air vise – CAUTION: Be sure to keep your fingers clear of the vise clamp. Be sure the starter is correctly engaged; you can determine this by listening to the gear noise when running the starter. When adjustment of the alignment is required (due to differences in housings) release the pneumatic vise first. The locking nuts are then loosened and the centering nuts adjusted (one on each side and two on bottom of mounting brackets) until the starter drive meshes properly – retighten the locking nuts. ELECTRICAL CONNECTIONS Connect the heavy red clamp to the starter battery terminal, connect the solenoid lead and “R” lead to the solenoid – as applicable. If the solenoid lead is not used, like on Ford starters, be sure it does not touch ground as it has voltage applied to it during the tests and the panel fuse will blow out if the lead touches ground. (Unplug it from the front panel). OT-0711 FREE RUN TEST 1. Set load control to free run (clockwise position). 2. Put ammeter switer in solenoid position. 3. Press cycle switch, observe solenoid reading, switch ammeter to starter position. 4. Observe “R” light (on Delco starters). 5. Observe oscilloscope pattern for definition of problem areas. 6. Release cycle switch, observe meter readings. These readings will be displayed until the cycle switch is pressed again or until the tester is turned off. LOAD TEST 1. Same as above, except that the load control is moved into the load position prior to step #5. This simulates car load conditions. NOTE: The starter should be run for 1 to 5 seconds or until the readings stabilize. NOTE: To develop a standard of acceptance, average the amp readings to 10 good starters and allow plus or minus 15 percent for limits. MAINTENANCE Lubricate pillow block assemblies Weekly Check oi] level in reservoir tank Monthly Remove vent cap, dip screw driver into tank – 071 should be 2-24 inches from the top (DO NOT OVER FILL – OIL NEEDS ROOM TO EXPAND WHEN HOT). If oil is dirty or sludge has formed, clean system and replace with 10/30 oil. 0il fan motors. Annually Remove side panels to blow dirt from tester As required Empty water from air regulator. As required Check 011 in air-oiler, fill 4% way with Marvel lubricating oil. As required Locking Nuts > – caren: _ He. – | Locking Nuts x : TYPICAL CONNECTIONS DELCO ¢ FORD FORD WITH DELCO SCLENOID CHRYSLER OT-0711 Symbol] R3 CR3-6 Tl & T2 T3 74 Bl & B2 K] K2 $3 DS1 & DS2 F3 & 4 F2 F] PCB1 PCB2 $2 PART LISTING (Electrical) Description Shunt – Solenoid 100A, 100 mu Shunt – Starter Amps 500 A, 50 mu Diode – High current power supply Transformer – High current power supply Transformer – Step down Transformer – Printed circuit power supply Fan – 220 volt Solenoid – High current Relay – Hold circuit Switch – Ammeter Bulb – 1891 Fuse Holder – 3 AG fuses Fuse – For local disconnect box Fuse – Solenoid, 20 Amp Fuse – Meters & Electronics, 0.5 Amp Printed Circuit Board – For scope Printed Circuit Board – Tachometer Test Lead – Scope, red Test Lead – Scope, black Test Lead – Solenoid Test Lead – “R” terminal Cycle Switch – To test units Part Number AT-0277 AT-0515 CT-5124 DT-0001 DT-0026 DT-1008 DT-1291 GT-1005 GT-1023 GT-1063 HT-1014 JT-0004 JT-0032 JT-0041 JT-1000 TT-1133 TT-5139 VT-0034 VT-0035 VT- 0127 VT- 0084 XT-2051