“onâ„¢ FILE IN THE GHX O, PTestaniTe SERVICE MANUAL GENERATOR SECTION (Issued 3-16-78 VOLTS 12 VENTILATED No RATED OUTPUT 6 Amperes POLES 2 BRUSHES 2 CONTROL Vibrating Current- Voltage Regulator. BEARINGS Ball at drive end. Absorbent bronze at commutator end, ROTATION See Tabulation. LUBRICATION Periodically add 5 dropa of medium engine oil to the End Head Oilers. At overhaul, pack open ball bearings 1/4 to 1/2 full with a good ball bearing lubricant. NOTE – Some ball bearings are sealed. These units are prelubricated and require no additional iubrication, BRUSH SPRING TENSION 35-53 ouncea with new brushes, Brush spring tension is measured with the scale hooked in the hole in the end of the brush arm and pulled on a line perpendicular to the top of the brush. The tension is read just as the arm leaves the brush. GROUND POLARITY See Tabulation, COMMUTATOR END HEAD Do not damage the commutator end felt wick when installing the head on the armature shaft. This ig best accomplished by removing the wick and re-installing it after the generator is assembied. Be aure wick lies on the bottom of the oil pocket and fill the pocket 1/2 full with Light greage. FIELD COIL DRAW (70°F) 1.17 to 1.23 amperes at 10,0 volts. MOTORING DRAW (70°F,} 1.9 to 2,1 amperes at 10.0 volta. (Have field terminal grounded to frame. } OUTPUT TEST (70°F.) 14.2 volts, 2.0 amperes at 550 maximum RPM. 15.0 volts, 6,0 amperes at 710 maximum RPM. Do not operate this type generator at more than 6,0 amperes for any length of time as to do 60 may result in burned armature and field windings. Unit Rotation Ground Polarit Internal Wirin GHX-4801M cw Positive Figure 1, GHX -4801NM cw Negative Figure 1. GHX -4802M CCW Positive Figure 2, GHX -4802NM cc Negative Figure 2, GHX – 4803 Cw Negative Figure 1, GHX – 4804 cCW Negative Figure 2, ARMATURE TERMINAL ARMATURE FIELD TERMINAL fie TERMINAL INSULATED BAUSH INSULATED BRUSH GROUNCED BRUSH . VEWED FOnd COMMUTATOR ENO VIEWED FROM COMMUTATOR END Figure 1, Figure 2. Printed in U.S.A.