Printed in U.S.A. WX prestolite_“ Pump Motor SERVICE Page 1 of 2 INFORMATION Issued 2/15/82 VOLTAGE 72 ROTATION See Tabulation | BRUSHES 8 | POLES 4 VENTILATED Yes FRAME DIAMETER 7-1/8″ LUBRICATION None required. Prelubricated and sealed ball bearings used at both ends of motor. FIELD RESISTANCE (77°F /25°C) .0116 to .0132 ohms measured between “S” terminal and field strap. ARMATURE TEST These armatures have standard winding connections and can be tested on a growler using a metal strip or hacksaw blade to locate shorted windings. COMMUTATOR Minimum diameter 2.938″. Replace armature when commutator has worn to this dimension. BRUSH REPLACEMENT Replace brushes when they have worn to a length of 9/16″ or less. SPRING TENSION 30 to 36 ounces with new brushes. Measure with a spring scale hooked under the brush spring at the brush. Pull the scale on a line opposite the line of force exerted by the brush spring and take the reading just as the brush spring leaves the brush. TEST CONNECTIONS (Reversible Motors) CWDE CCWDE Connect A-1 to battery positive Connect A-2 to battery positive Connect A-2 to S-1 Connect A-1 to S-1 Connect S-2 to battery negative Connect S-2 to battery negative TEST SPECIFICATIONS (77°F/25°C) Test reversible motors in both directions of rotation. Terminal Maximum Torque Voltage Amperes RPM Ft. Lbs. No Load Test 12 20 1270 Min. 0 Light Load Test 73.12 81 2740/3160 10 File in the MIB Pump Motor Page 2 of 2 Issued 2/15/82 UNIT MTB-4001 MTB- 4002 VIEWED FROM DRIVE END FIGURE i IX prestolite INF SERVICE ORMATION ROTATION CCWDE Reversible INTERNAL WIRING Figure 1 Figure 2 VIEWED FROt COMMUTATOR END FIGURE 2