Printed in U.S.A. ©, prestolite. SERVICE INFORMATION VOLTAGE 72 ROTATION Reversible BRUSHES 8 POLES 4 VENTILATED Yes LUBRICATION FIELD RESISTANCE ARMATURE TEST COMMUTATOR BRUSH REPLACEMENT SPRING TENSION TESTING NOTE TEST CONNECTIONS CWDE Connect S-1 to battery positive Connect S-2 to A-1 Connect A-2 to battery negative File in the L-600 SERVICE MANUAL MTO Traction Motors Page 1 of 2 Issued 4/1/88 FRAME DIAMETER 7-1/4″ None required. Prelubricated and sealed bal] bearing used at the commutator end of the motor, The drive end bearing is furnished by the customer. 77°F /25°C. .0212 to .0257 ohms measured between terminals S-1 and 5-2, These armatures have standard winding con- nections and can be tested on a growler for shorted windings. Minimum diameter 2.938″, Replace armature when commutator has worn to this dimension. Replace brushes when they have worn to a length of 9/16″ or less, 30 to 36 ounces with new brushes. Measure with a spring scale hooked under the brush spring at the brush, Pull the scale ona Tine opposite the line of force exerted by the brush spring and take the reading just as the spring leaves the brush, These motors are supplied to the customer without a drive end bearing. The armature shaft is supported by a bearing in the customer’s mounting. DO NOT BENCH TEST WITHOUT THE CUSTOMER MOUNTING. CCWDE Connect S-1 to battery positive Connect $-2 to A-2 Connect A-1 to battery negative —- TRACTION MOTOR SECTION MTO we Traction Motors &X prestolite. Page 2 of 2 SERVICE Issued 4/1/88 INFORMATION TEST SPECIFICATIONS 77°F /25°C. TERMINAL MAX IMUM TORQUE VOLTAGE AMPERES. RPM FT. LBS, No load test 12 14 1340 Min. 0 Light load test 66.6 198 1900 to 2195 30 UNIT MTO0-4001 MTO-4002 Internal Wiring VIEWED FROM COMMUTATOR END