Instructions No. 2907C FAIRBANKS-MORSE TYPES FM-XV4B7 AND FM-XVE4B7G MAGNETOS Adapted only to Wisconsin VE4, VF4, and VP4D Engines — = ATSSRE FM-XV4B7 5034R-A FM-XVE4B7G Field Service and Adjustment Information GENERAL DESCRIPTION Types FM-XV4B7 and FM-XVE4B7G magnetos are special units designed and built foruse on Engine Models VE4, VF4, and VP4D, manufactured by the Wisconsin Motor Corporation, These engines are all modifications of the same basic design, each having a firing interval of 180°-270°-180°-90°. Types FM-XV4B7 and FM-XVE4B7G magnetos, each having a four pole rotor anda four lobe cam, meet this requirement by producing four sparks per revolution of the rotor, which runs at crankshaft speed. In a complete cycle of two engine revolutions, four sparks are used for ignition and four fire in the exhaust. These magnetos have the standard SAE flange mounting, but have a specialcoupling and drive gear arrangement which requires an extended rotor shaft. SERVICE PROCEDURE Improper functioning of the magneto is often believed to be the cause of engine difficulty arising from other sources, such as a flooded carburetor, insufficient fuel or air, loose ignition connections, or a defective spark plug. Since a brief engine inspection will often localize the trouble before the magneto is reached, it prevents maladjustment of parts in good condition. Type FM-X magnetos are built insealedframes and should be opened only when it is certain that the ignition spark produced is unsatisfactory. This condition maybe determined by ig- nition spark tests which are easily made in the field. TESTING THE IGNITION SPARK With properly adjusted spark plugs in good condition, the ignition spark should be strong enough to bridge a short gap in addition to the actual spark plug discharge. This may be determined by holding the end of the ignition cable not more than 1/16 in. away from the spark plug terminal. The engine should not misfire when this is done. Ignition tests made while any part ofthe system is wet are useless. TESTING THE MAGNETO SPARK Remove all the ignition cables from the magneto end cap sockets and insert a short, stiff wire in one of the Instructions No. 2907C Supersedes Instructions No. 2907B June l, 1954 sockets. Bend this wire to within 1/8 in. of the engine block. Turn the engine over slowly one complete revo- lution and watch carefully for the spark discharge which should occur every time the impulse coupling releases. Repeat this test withthe wire in each ofthe other sockets If a strong sparkis observed withthe wire in each socket, it is recommended that the magneto be eliminated as the source of difficulty and that the cables, terminals, and spark plugs be thoroughly inspected. If nospark occurs, the ignition switch should be examined to make certain it has not accidentally become closed. END CAP COVER REMOVAL If no spark is obtained from one or more of the mag- neto terminals, remove the end cap cover, taking care not to damage the gasket. Remove the distributor rotor and clean the distributor compartment thoroughly, ob- serving whether the air passages are open or clogged. IT IS EXTREMELY IMPORTANT THAT THESE AIR PASSAGES BE KEPT FREE OF DIRT AND OTHER FOR- | EIGN MATTER. Examine the high-tension lead brush “and replace itifnoticeably worn or damaged. This brush should move freely inits holder and shouldbe under slight spring pressure. SERVICE OF BREAKER POINTS Before examining the breaker points, it is first necessary to remove the end cap, which is sealed to the metal-frame by a gasketjoint. The breaker points should then be inspected for evidence of pitting or pyramiding. A small tungstenfile or fine stone maybe used to resur- face the points except in the case of badly worn or pitted points, which should be replaced. If it is necessary to resurface or replace the breaker points, it will also be necessary to readjust them to their proper clearance, which is 0.015 in. at full separation. This adjustment is made inthe following manner: Loosen the locking screws identified in Fig. 1 shown below. Then move the contact support until the proper breaker point clearance is ob- tained. This is accomplished by means of a screwdriver inserted in the horizontal slot at the bottom of the contact support and pivoted between the two small bosses on the Page 2 2907C TYPES FM-XV4B7 AND FM-XVE4B7G MAGNETOS Instructions COIL CONDENSER 4 LOBE CAM DETERMINE THE BREAKER POINT GAP WHEN OPEN. ADJUST TO 0O.0I5 INCH. LOCKING SCREWS BREAKER ARM TERMINAL SCREW Fig. 1. End View of Type FM-XV4B Magneto. bearing support. Lock the assembly in place by tighten- ing the locking screws and take a final measurement of the breaker point gap after the locking screws are tight- ened. FURTHER FIELD SERVICE NOT RECOMMENDED The cam felt wick, if dry or hard, shouldbe replaced by a new factory-impregnated wick. This isdone by sub- stituting a new cam wick and holder assembly for the old assembly. Other thanthis, Type FM-XV magnetos donot req