FAIRBANKS-MORSE MAGNETO DIVISION BELOIT, WISCONSIN INSTRUCTIONS 2911C SUPERSEDES INSTRUCTION 2911 B September 1957 Service and Adjustment Information GENERAL DESCRIPTION Modern ignition systems are carefully designed to provide quick, easy starting and maximum dependability of operation with minimum adjustment and service. Due to advanced engineering and sturdy construction, the Fair – banks-Morse magnetos have become field performance leaders. The compact powerful Alnico rotor assures an intensely hot sparkeven under the most difficult operating conditions. Fieldadjustments are rarelynecessary and, although simple, they should be made only in accordance with the following instructions. SERVICE PROCEDURE Improper functioning of the magneto is often believed to be the cause of engine difficulty arising from other sources, such asa flooded carburetor, insufficient fuel or air, loose ignition connections, or a defective spark plug. A brief engine inspection will usually localize the trouble before the magnetois reached, andoften prevents maladjustment of parts in good condition. Type FM-X magnetos are built in vented frames which should not be opened unless it is certain that the ignition spark is un- satisfactory. This conditionmay be determined by igni- tion spark tests can be easily made in the field. TESTING THE IGNITION SPARK With spark plugs properly adjusted and in good con- dition, the ignition spark should be strong enough to bridge a short gap in addition to the actual spark plug discharge. This may be determined by holding the end of each ignition cable 1/16 in. away from the spark plug terminal while the engine is running. The engine should not misfire when this is done, Ignition tests made while any part of the system is wet are useless. TESTING THE MAGNETO SPARK Tag the ignition cables to insure their proper re- placement in the end cap cover, then remove all the ig- nition cables from their respective sockets and insert a short, stiff wire in one of the sockets. Bend this wire to within 1/8 in. of the engine block. Turn the engine over slowly two complete revolutions and watch carefully INSTRUCTIONS 2911C September 1957 for the spark discharge which should occur once during the cycle at the instant the impulse coupling releases. Repeat this test with the wire in each of the other sock- ets. Ifa strong spark is observed with the wire in each socket, it is recommended that the magneto be elimin- atedasthe source of difficulty and that the cables, termi- nals, and spark plugs be thoroughly cleaned and inspected. If no spark occurs, the ignition switch should be exam- ined to make certain it has not accidentally become closed. END CAP COVER REMOVAL If no sparkis obtained from one or more of the mag- netoterminals, remove the end cap cover, being careful not to damage the gasket. Remove the distributor rotor and clean the distributor compartment thoroughly, ob- serving whether the air passages are open or clogged. ITISIMPORTANT THAT THESE AIR PASSAGES BE KEPT FREE OF DIRT AND OTHER FOREIGN MATTER. If these passages are obstructed for any appreciable length of time, all metal parts within the end cap will become corroded. Examine the high-tension lead brush and replace it if noticeably worn or damaged. This brush should move freely in its holder and should be under slight spring pressure, SERVICE OF BREAKER POINTS Before examining the breaker points, itis first nec- essary to remove the end cap, which is sealed to the metal frame bya gasketjoint. The breaker points should then be inspected for evidence of pitting or pyramiding. A tungsten file or fine stone may be used to resurface the points, Badly worn or pitted points should be re- placed. If it is necessary to resurface or replace the breaker points, itwillalsobe necessary to readjust them to their proper clearance of 0.015 in. at full separation. This adjustment is made inthe following manner: Loosen slightly the two contact support locking screws, Fig. 1. Then move the contact support until the proper breaker point clearance is obtained. This is accomplished by means of a screwdriver inserted in the horizontal slot at the bottom of the contact support and pivoted between PRINTED IN U.S.A. File Section – TYPE FM-X CcoIL~ CONDENSER MEASURE BREAKER POINT GAP WHEN OPEN. ADJUST TO 0.015 INCH. BREAKER ARM LIE LOCKING { 06 fend screws Ih af BREAKER ARM SS TERMINAL SCREW Fig. 1. End Views of Type FM-X Magnetos the two small bosses onthe bearing support. This causes a slight rotation of the contact support about the small boss on the bearing support just above the breaker arm terminal screw. Lock the assembly in place by tighten- ing the locking screws, and take a final measurement of the breaker point gap after the locking screws are tight- ened, FURTHER FIELD SERVICE NOT RECOMMENDED The cam felt wick, if dry or hard, should be re- placed by a new factory-impregnated wick. Other than this, Type FM-X magnetos do not require field lubrica- tion and any