ERA Office: Monday – Friday 9:00-5:00 CST

275 W. BROWN ST, UNION, MO 63084

636-584-7400

office@electricalrebuilders.org

ERA Tech Helpline: 636-584-TECH (8324)

FAIRBANKS-MORSE MAGNETO DIVISION BELOIT, WISCONSIN Instructions 2921B Supplements Instruction 2921 April 1957 fe TYPE FM-X ONE CYLINDER MAGNETOS FOR WISCONSIN MOTOR CORPORATION § NORSE TYPZ FM PAL PAT PEND, BASE MOUNTING der engines. The variations of the Type FM- X1A7 magneto are all of a special base mounting design with a shaft height of 35 mm, and the modifications of the Type FM-X1B7 unit have a special mounting flange. The magnetic and electrical circuits of all units are identical, with a two pole magnetic rotor anda single lobe cam producing one ignition spark per revolu- tion. Rotation of the base-mounting types is ounterclockwise when viewed from the drive end, while the flange-mounting magnetos rotate clockwise. All are fitted with dependable, sin- gle pawl impulse couplings which facilitate starting by providing an intensified and retarded ignition spark at low engine speeds. SERVICE PROCEDURE Improper functioning ofthe magneto is often believed to be the cause of much engine trouble arising from other sources, such as a flooded carburetor, an obstructed air intake, defective ignition connections, or corroded spark plug points. Since a brief engine inspection will often locate the trouble before the magneto is Instructions 2921B April 1957 FLANGE MOUNTING Service and Adjustment Information GENERAL DESCRIPTION The one cylinder magnetos whose parts are listed inthis instruction sheet were built specifi- cally for application on Wisconsin single cylin- reached, it prevents maladjustment of magneto parts in good condition. It is suggested that the magneto be opened only when it is certain that the ignition spark produced is unsatisfactory. This condition may be determined by simple tests which are easily made in the field. TESTING THE IGNITION SPARK With a properly adjusted spark plug in good condition, the ignition spark should be strong enough to bridge a short gap in addition to the actual spark plug discharge. termined by holding the end of the ignition cable not more than 1/16 in. away from the spark plug terminal. The engine should not misfire when this is done. Ignition tests made while any part of the system is wet are useless, TESTING THE MAGNETO SPARK Remove the ignition cable from the end cap socket and insert a short piece of stiff wire. Bend this wire to within 1/8 in. of the engine block. Turn the engine over slowly and watch carefully for the spark which should occur at the instant the impulse coupling releases. Ifa strong spark is observed, it is recommended that the magneto be eliminated as the source of the difficulty and that the cable, terminals, and Printed in U.S.A, File Section – TYPE FM – X This may be ders. 4 Page 2 2921B ONE CYLINDER MAGNETOS FOR WISCONSIN MOTOR CORPORATION Instructions spark plug be thoroughly inspected. SERVICE OF BREAKER POINTS Remove the magneto end cap and compare the arrangement of parts with the drawings of Fig. 1. The breaker points should then be in- spected for evidence of pitting or pyramiding. A small tungsten file or fine stone may be used to resurface the points, except in the case of badly worn or pitted points, which shouldbe re- placed. Removal of worn points may be ac- complished by removing the fulcrum pin snap ring, the breaker arm terminal screw, and the contact support locking screws, all of which are identified in Fig. l. If itis necessary to re- surface or replace the breaker points, it will also benecessary to adjust them to their proper clearance, which is 0.015 in. at full separation, This adjustment is made in the following man- colt CONDENSER MEASURE BREAKER POINT GAP WHEN OPEN. ADJUST TO 0.015 INCH FULCRUM PIN SNAP RING BREAKER ARM BREAKER ARM TERMINAL Fig. 1. End Views of Type FM-X Magnetos ner: Loosen the contact supportlocking screws, then move the contact support until the proper breaker point clearance is obtained. This is accomplished by means ofa screwdriver in- serted in the horizontal slot at the bottom of the contact support and pivoted between the two small bosses on the bearing support. Lock the assembly in place by tightening the locking screws and make a final measurement of the breaker point gap after the locking screws are tightened, -SEALING MAGNETO Type FM-X magnetos are sealed at the factory against the entry of dust and moisture through the use of a varnish-coated gasket joint. Opening the magneto for breaker point adjust- ment or other service necessitates resealing of the magneto upon reassembly. The surfaces between the magneto frame and the end cap should be cleaned thoroughly, a new gasket should be provided, andthe joint shouldbe sealed witha coating of FMCO2 Gasket Sealing Varnish, SPECIAL DRIVE GEAR Flange mounting magnetos for Wisconsin motors require a drive gear fitted to the im- pulse coupling by means of an extended rotor shaft. To engage the slotted drive gear cor- rectly with the drive lugs of the coupling, the magneto rotor shouldbe turned by hand until the coupling pawl engages the stoppin i

File Type: pdf
File Size: 6 MB
Categories: magnetos