ERA Office: Monday – Friday 9:00-5:00 CST

275 W. BROWN ST, UNION, MO 63084

636-584-7400

office@electricalrebuilders.org

ERA Tech Helpline: 636-584-TECH (8324)

Instructions No. 2959A Supersedes Instructions No. 2959 FAIRBANKS-MORSE TYPES FM-E6A AND FM-E6B RADIO-SHIELDED MAGNETOS Field Service and Adjustment Information APPLICATION Type FM-E6B magnetos are built for continuous heavy-duty operation on six-cylinder engines requiring complete radio-shielding of the ignition system. Radio- shielding of the magneto is accomplished by enclosing the entire unit in a grounded metal frame equipped with special venting ports. Threaded bushings are provided for connection to the flexible, woven metal sheaths which are used to shield the high tension lead cables. For ap- plications in which a higher degree of shielding is re- quired, magnetos with feed-through condensers are available. SERVICE PROCEDURE Improper functioning of the magneto is often believed to be the cause of engine difficulty arising from other sources, such as a flooded carburetor, insufficient fuel or air, loose ignition connections, or a defective spark plug. Since a brief engine inspection will often locate the trouble before the engine is reached, it prevents malad- justment of parts in good condition. It is suggested that the magneto be opened only when itis certain that the ig- nition spark produced is unsatisfactory. This condition may be determined by simple tests which are easily made in the field. TESTING THE IGNITION SPARK With properly adjusted spark plugs in good condi- tion, the ignition spark shouldbe strong enough to bridge a short gap inaddition to the actual spark plug discharge. The test is made with the engine running. Remove the upper half of the spark plug radio shields and hold each ignition cable terminal in turn not more than 1/16 in. away from the spark plug terminal, taking the usual pre- cautions against electric shock. The engine should not misfire when this test is made. However, tests made while any part of the system is wet are useless. Instructions No. 2959A June 1, 1954 File Section- TYPE FM-X TESTING THE MAGNETO SPARK Tag the high-tension cables to insure their proper replacement. Remove the cable outlet nuts to remove the metal cable sheaths, and pull the cables out of the distributor block sockets. In the case of Types FM- E6B16F and FM-E6B97 magnetos, which incorporate an end cap cover, it will be necessary to remove this cover and to loosen the six cable outlet knobs which hold the wires in place in the distributor block. Remove 1/2 in. of the insulation from the end of a short length of stiff, rubber-covered wire and insert in place of the high- tension cable. Be sure this wire reaches the bottom of the socket and contacts the brass insert. Bend the other end of the wire to within 1/8 in. of the engine or magneto frame and watch closely fora spark between the wire and the engine (or magneto) frame every sixth time the im- pulse coupling releases when the engine is turned over slowly. Test each of the sockets in turn; if a strong spark is observed with the wire in each socket, it is recommended that the magneto be eliminated as the source of difficulty and that the cables, terminals, and spark plugs be thoroughly inspected. If no spark occurs, the ignition switch should be examined to make certain it has not accidentally become closed. SERVICE OF BREAKER POINTS If no spark is obtained from one or more of the mag- neto terminals, the end cap assembly should be removed from the magneto frame by removing the four end cap screws. Then examine the carbon brush in the center of the distributor block and replace it if noticeably worn or damaged. This brush should move freely in its holder and should be under slight spring pressure. Next, in- spect the breaker points for evidence of pitting or pyra- miding. A small tungsten file or fine stone may be used to resurface the points except in the case of badly worn or pitted points, which shouldbe replaced. If it isneces- Page 2 2959A sary to resurface or replace the breaker points, it will also be necessary to adjust them to their proper clear- ance, which is 0.015 in. at full separation. This adjust- ment is made inthe following manner: Loosen the contact support locking screws, identified in Fig. 1. Then move the contact support until the proper breaker point clear- ance is obtained. This is accomplished by means ofa screwdriver inserted in the horizontal slot at the bottom of the contact support and pivoted between the two small bosses on the bearing support. Lock the assembly in place by tightening the locking screws and take a final measurement of the breaker point gap after the locking screws are tightened. Oil film canbe removed from the breaker points by using a small brush and a small quan- tity of petroleum solvent. MOLDED COIL DISTRIBUTOR GEAR ADJUST BREAKER POINTS TO 0.015″ WHEN OPEN. LOCKING SCREWS BREAKER ARM TERMINAL SCREW Fig. 1. End View of Type FM-E Magneto. FURTHER FIELD SERVICE NOT RECOMMENDED The cam wick, if dry or hard, should be replaced by anew factory-impregnated wick. This is done by sub- stituting a new c

File Type: pdf
File Size: 5 MB
Categories: magnetos