Instructions No. 2867A Supersedes Instructions No. 2867 FAIRBANKS-MORSE FAIRBANKS-MORSE TYPE FM-JE4 MAGNETOS FOR RADIO-SHIELDED APPLICATIONS Also Applies to Type FM-JFE2 Magnetos Field Service and Adjustment Information APPLICATION Type FM-JE4 magnetos are built for operation on standard four cylinder engines which require complete radio shielding of the ignition system. Radio shielding of the magneto is accomplished by enclosing the entire unit in a grounded metal frame equipped with special vents. Threaded bushings are provided for connection to the flexible, woven metal sheaths whichareused to shield the high tension leadcables. The primary ground termi- nal is also arranged for connection to a shielded cable on installations requiring a remote control switch, TESTING THE IGNITION SPARK With properly adjusted spark plugs in goodcondition, the ignition spark should be strong enough to bridge a short gap in addition to the actual spark plug discharge. This may be determined by removing the upper half of the spark plug radio shield and holding the ignition cable end not more than 1/16 in. away from the spark plug terminal, The engine should not misfire when this is done. TESTING THE MAGNETO SPARK Disconnect each high tension cable from its respec- tive spark plug and lay the cables on the engine block adjacent to their respective spark plugs to insure proper replacement. With the terminals 1/8 in. from the engine block, slowly turn the engine over two com- plete revolutions and watch carefully for a spark dis- charge which should occur every time the impulse coup- ling releases. If a strong spark is observed between one of the terminals and the engine blocR each time the coupling releases, it is recommended that the magneto and all its connections be eliminated as the source of difficulty. If strong sparks are observed from only one, two, or three of the terminals, a defective high tension cable is indicated. Remove the questionable cable from Instructions No. 2867A September 1, 1955 its socket. This may be done by unscrewing the high tension cable outlet nut in the end cap cover. Insert a short, stiff wire in the socket and bend this wire to within 1/8 in. of the engine block. Turn the engine over slowly two revolutions and watch for the spark which should oc- cur once during the cycle. A strong spark indicates a defect in the high tension cable for that outlet. SERVICE OF BREAKER POINTS Remove the high tension cables as described in the previous paragraph and take the endcap off the frame by removing the four end cap screws. Examine first the carbon brush in the center of the distributor block, and replace it if noticeably worn or damaged. This brush should move freely in its holder and should be under slight spring pressure. Clean the screens in the vents. Inspect the breaker points for evidence of pitting or pyramiding. A small tungsten file or fine stone may be used to resurface the points except in the case of badly worn or pitted points, which should be replaced. If itis necessary to resurface or replace the breaker points, it will also be necessary to adjust them to their proper clearance, whichis 0,020in. at full separation. This adjustment is made in the following manner: With the breaker arm riding the high part of the cam, or one of the lobes, loosen the contact support locking screw very slightly and turn the eccentric head adjusting screw until the proper gap is obtained. Then tighten the locking screw and take a final measurement of the breaker point gap after the screw is tightened. Oil film can be re- moved from the breaker points by using a small stiff brush and a small quantity of petroleum solvent. FURTHER FIELDSERVICE NOT RECOMMENDED In general, it is recommended that difficulties due to the coil, condenser, or other causes be investigated by a Fairbanks-Morse Authorized Service Station, which File Section- TYPE FM-J Page 2 2867A FAIRBANKS-MORSE TYPE FM-JE4 MAGNETOS coIL CONDENSER LOCKING SCREW DETERMINE THE BREAKER POINT GAP WHEN OPEN ADJUST TO 0.020″ ADJUSTING SCREW BREAKER ARM-————+ BREAKER ARM TERMINAL SCREW Fig. 1. End View, Types FM-JFE2 and FM-JE4 Magnetos has the necessary equipment for effective service. In emergencies either the coil or condenser can be replaced in the field without special tools. To remove the coil from the magneto the magnetic rotor gear must first be taken off the shaft, after which the bearing plate can be removed. The setscrews holding the coil lamination as- sembly should then be loosened and the coil pulled out of the frame, The magnetic rotor is locked in the special drive end thrust ball bearing and cannot be pushed or driven from the frame without first releasing the rotor shaft. Removal of the magnetic rotor is described in Bulletin FM71B. It is also recommended that no attempt be made to oil or grease the bearings except during complete disas- sembly and overhaul by an Authorized Service Station, Type FM-JE4 magnetos are designed to operate for lon