Instructions No. 2833A Supersedes Instructions No. 2833 FAIRBANKS-MORSE TYPES FM-K4A AND FM-K4B MAGNETOS Field Service and Adjustment Information FAIRBANKS MORSE FAIR PALPEND PPE Bi oe Type FM-K4A GENERAL Improper functioning of the magnetois often believed to be the cause of much engine trouble arising from other sources. The service chart below gives alogical procedure to follow when an engine fails to start, is hard to start, or missesinoperation. Since the useof this table locates the trouble in many cases before the magneto is reached, it prevents all-too-common maladjustment of parts in good condition. Itis suggested that the magneto be opened only when it is certain that the ignition spark produced is un- satisfactory. This condition may be determined by simple tests which are easily made in the field. TESTING THE MAGNETO SPARK Remove all the ignition cables from the magneto end cap sockets and insert a short, stiff wire in one of the sockets. Bend this wire to within 1/8 in. of the engine block. Turn the engine over slowly two complete revolu- tions and watch carefully for the spark discharge which should occur once during the cycle at the instant the im- pulse coupling releases. Repeat this test with the wire in eachof the other sockets. Ifa strong spark is observed with the wirein each Socket, itis highly recommended that the magneto be eliminated as the source of d iculty and that the cables, terminals, and spark plugs be thoroughly inspected. If no spark occurs, the ignition switch should be examined to make certain it has not accidentally become closed. Type FM-K4B DISTRIBUTOR COVER REMOVAL If no spark is obtained from one or more of the magneto terminals, take off the distributor end cap by removing the four end cap screws. Then check the following details: (a) Inspect the carbon brushes. These brushes should move freely in their holders and should be under slight spring pressure. Replace brushes which are wornor irregu- lar. (b) Clean the distributor disc withaclean cloth and carbon tetrachloride. Do not use sandpaper. SERVICE OF BREAKER POINTS Carefully examine the breaker points for evidence of pitting or pyramiding. Asmall tungsten file or fine stone may be used to resurface the points except in the case of badly worn or pitted points, which should bereplaced. The entire breaker mechanism may be easily removed from the magneto frame, eliminating the possibility of dropping fil- ings in the housing. If it is necessary to resurface or replace breaker points, it will also be necessary to read- just then to their proper clearance, which is 0.020 in. at full separation. This adjustment is made by loosening the two locking screws (Fig. 1) of the stationary point bracket, turning the eccentric head adjusting screw until the proper position has been obtained, and locking the as-— sembly in place by tightening the locking screws. A final measurement of the breaker point gap should be made after the locking screws are tightened. TROUBLE POSSIBLE CAUSE SUGGESTED REMEDY . Flooding Hot or cold engine; over-rich fuel mixture. Insufficient | Hnpty fuel tank; clogged fuel fuel or air |lines; clogged air intake. CC. Ignition Loose or corroded terminals; broken connections cables; short circuited switch. Spark plugs Corroded, worn or damaged points; cracked or carbonized insulators. Dry out cylinders. Crank engine slowly with fuel shut off; or let engine stand idle for a short time. Replenish fuel supply. Clean fuel system and check carburetor. Clean air intake system. Clean or replace cable terminals. Inspect soldered or clamped joints. Test and replace cables. Check ignition switch. New plugs. Cleanpoints and insulators. Adjust points to rec- ommended opening. Never attempt to adjust center electrode. Points, impulse coupling. Instructions No. 2833A September 15, 1948 See instructions beginning “Testing the Magneto Spark”. File Section- TYPES FM, FM-K, FM0 Page 2 2833A FAIRBANKS-MORSE TYPES FM-K4 MAGNETOS Instructions OISTRIBUTOR GEAR ———— CAM FELT WICK _-— DISTRIBUTOR ROTOR CAM FELT WICK— HOLDER 4 BREAKER ——— POINTS pane gamer, Ke ~——CONDENSER ECCENTRIC HEAD [ADJUSTING SCREW / TERMINAL SCREW— so \— BREAKER ARM ~STATIONARY CONTACT SUPPORT BRACKET Fig. 1. Breaker Plate Assembly. LUBRICATION The cam felt wick, if dry orhard, should be replaced by a new factory-impregnated wick. Other than this, Types FM-Kl, magnetos donot require field lubrication and any at- tempt to oil or grease the bearings is inadvisable. The ball bearing is packed with the finest grade of high melting point grease (FMCO3), and the porous oilite sleeve bearings are mounted in bearing supports which include reservoirs containing an additional quantity of a particularly suitable grease (FMCOl). These lubricants should be renewed only during a complete overhaul of the magneto by a Factory- Authorized Magneto Service Station. REASSEMBLY AND SEALING Before replacing the distributor end cap on the magneto frame, clean the contact surfaces