FILE IN THE ALL e, PTeStONte SERVICE MANUAL ALTERNATOR SECTION (Issued 3-16-78) VOLTS 24 VENTILATED Yes RATED GUTPUT 20 Amperes BRUSHES 2 CONTROL Voltage Regulator ROTATION Bi-directional BEARINGS Sealed, Ball at both ends, LUBRICATION Bearings are pre-lubricated, No additional lubrication is necessary. BRUSH SPRING TENSION 9.5 to 11 ounces when spring is compressed to 1/4 inch. END PLAY Negligible. Unit should rotate freely without binding. A condition of end play would indicate improper assembly, damage or exces- sive wear, GROUND POLARITY Negative. NOTE: DO NOT ATTEMPT TO POLARIZE AN ALTERNATOR – DAMAGE MAY OCCUR TO THE ALTERNATOR, REGULATOR or CIRCUITS. ROTOR CURRENT DRAW (70°F.),.9 to 1.1 maximum amperes at 20.0 volis. OUTPUT TEST (70°F.) 26.3 volts, 10 minimum amperes, 1500 RPM alternator speed. 28.4 volts, 20 minimum amperes, 2700 RPM alternator speed. INTERNAL UNIT WIRING ALL-5201, 4,5 Figure 1. ALL-6001 Figure 2. ALL-6202 Figure 3. ALL-6301 Figure 4. ALL-6302 Figure 4, Figure 1. Figure 2. Printed In U.8.A. SQ Prestolite SiN MANUAL (ALL continued Figure 3, Figure 4.