Lucas M50 starters with double -contact solenoids Part Il COLUMN BY NATHAN UNGER WITH WES GRUENINGER SR. Understanding the starter re you sitting down? Here goes: First we start with a wiring dia- gram (see Figure 7). Notice that all the field coils are in par- allel to each other (4 shunt coils) except for the one which is connected to an inde- pendent set of contacts (M1). Refer again to Figure 2 and Figure 3, in the December issue, page 8. Installed on the machine, the power on B+ of the starter is present all the time. Power is applied to the S terminal via the start button/ignition switch, and current flows through both solenoid coils—a total of 92A on one I tested. The hold-in coil is connected directly to ground. It is active the whole time the S circuit is pow- ered up. The pull-in coil is grounded through the fields and the armature at the “motor” stud of the 3 coils (This is that sec- ond set I discussed earlier, M3 in Figure 3). As soon as the M3 contacts are closed, the pull-in coil will have 12V on both ends and no current will flow through it (see Figure 10). This prevents the pull-in coil from overheating and also lowers the current flowing through the ignition switch and other components of the S cir- cuit, down to about 16A. The pull-in coil B+ HOLD-IN DOUBLE- CONTACT SOLENOID BATTERY STARTER MOTOR Figure 7—M650 circuit diagram. does most of the work of pulling the plunger in and is wound with thicker wire than the hold-in coil. Even though it has the same number of turns as the hold-in coil, it draws a lot more current—about 76A by itself in my test unit. It works together with the hold-in coil and actually contributes to the soft start effort to clear tooth abutment. I’ve even seen a number of starters by other manufacturers where the soft start feature depends on the pull in coil current. Now let’s look at this in slow motion: Step 1: As the solenoid plunger starts to pull in, the drive starts to engage the ring gear. Almost immediately the M1 contacts close. This means that current flows through the single shunt coil. Together with the pull in coil current through M3, we now have enough current to make the armature rotate slowly. If it should happen that we get tooth abutment at first (see Figure 8), then the linkage will not allow the M3 contacts to close yet. (Exception: if your pinion clearance is excessive, it may allow the M3 contacts to close prematurely. That can cause milling of the gears.) But, during the time that the plunger is moving, the S circuit is carry- ing 92A. All this current is coming from the ignition switch! As soon as the M3 contacts close, that current drops to 16A. Step 2: As the armature rotates slowly, it clears the abutment position and engages the ring gear fully (see Figure 9). The linkage then allows the M3 contacts to close, giving full power to the remain- ing three field coils, allowing the starter to properly crank the engine. Step 3: In that small fraction of a sec- ond when the farmer quits cranking the engine, but before the solenoid contacts have time to release, there will be a cur- rent path from the power still available at the M3 stud, up to the now-released S ter- minal, then through the hold-in coil to ground (see Figure 10). Two things happen in that fraction of a second: 1. The current in the pull-in coil is reversed in direction, reversing its magnetic pull. 2. Current flows in series through the pull-in coil and the hold-in coil. Because of this, they both have the same amount of current—on my unit, about 13A. Remember Kirchhoff?* Current in a series cir- cuit is the same at all points. Since both coils have the same number of turns and the same amount of current, but opposite magnetic polarity, the net magnetic pull is zero. This allows the var- ious springs in the linkage to open the contacts and return the plunger and the drive. As an aside, notice that the pull-in coil is connected to M3, not to the motor stud of the single coil (M1). This means that if the M3 contacts don’t close, you will have high current continuously, instead of just momentarily. According to my test unit, that’s about 92A through the S switch the whole time the farmer is tor- menting his starter. This is one reason the solenoid coils get burned. Could this also burn out his ignition switch contacts? I’ve heard of that happening. In some machines, they have an extra relay to protect the ignition switch and also improve the available voltage to the solenoid. This relay can be retrofitted as well. See the article on the ERA website in the Technical Article Library called “Solving Problems Using Relays—or— Four Handy Uses for Bosch Relays” by Wes Grueninger and Bob Thomas— refer to Problem Fix no.1. To reiterate—the single burned field coil is a result of the second set of con- tacts not closing. That might be due to incorrect pinion clearance or worn/dirty contacts. Understanding contact voltage drop Contact voltage drop is a measure of how well the contacts conduc