ERA Office: Monday – Friday 9:00-5:00 CST

275 W. BROWN ST, UNION, MO 63084

636-584-7400

office@electricalrebuilders.org

ERA Tech Helpline: 636-584-TECH (8324)

MAGNETO FUNDAMENTALS Magneto Fundamentals Before going into the actual dismant- ling and servicing of magnetos,, it is advisable to have a good understanding of the magnetic and electrical princi- ples involved. By knowing these prin- ciples a serviceman is in a position to reason the construction of the various magnetos, will not depend to much on his memory, and oftentimes can figure things out for himself. ILLUST. 1–INDICATES HE PATH OF MAGNETIC LINES OF FORCE BETWEEN THE POLES OF AN ORDINARY HORSESHOE MAGNET. Illust. 1° shows a simple horseshoe magnet, found in the average magneto. This magnet will pick up tacks and nails and will affect the pointer in a compass. The attracting action is caused by a magnetic field in the vicinity of the magnet made up of magnetic lines of force which travel from the north pole at one end of the magnet, through the air to the south pole at the other end. It will be noted that the attractive force is greater nearer the magnet and less the farther away you go. ILLUST. 2–SHOWS A COIL OF WIRE CONNECTED TO A CURRENT METER. COIL IS LOCATED IN MAGNETIC FIELD. MOVEMENT OF COIL IN MAGNETIC FIELD WILL INDICATE A CURRENT THROUGH CURRENT METER. Illust. 2 shows, in addition toa horseshoe magnet, .a coil of wire placed in the magnetic field and connected to a current meter or better known as an am- meter. The ammeter will show a reading if.a current passes through the coil. While. the coil of wire is stationary in the magnetic field there is no reading on the meter; if the magnet is suddenly jerked away there is a reading on tne meter. Now if the magnet is suddenly moved back again there is a reading on the meter, but in the opposite direction. From this it can be concluded that the mere presence of magnetism in the vicin- ity of a coil produces no current but the change in magnetism does produce a current. The direction of current is determined by the direction of change in magnetism. It will also be -noted that if the. magnet is moved slowly a very slight reading on the meter results and if moved rapidly a larger reading re- sults. This snows that the speed at which the magnetic field is changed a- round the coil will directly affect the current induced in the wire. It has been shown that a current will be generated in the coil if placed ina changing magnetic field; however, this current will not have sufficient voltage to jump a gap in an ordinary spark plug. For this reason a transformer coil is used which steps up the low voltage in the primary coil to a high voltage in the secondary coil. The high voltage current produced in the secondary coil will jump an ordinary spark gap. A con- denser is used across the breaker points which acts as a shock absorber and helps produce a sudden break in the primary circuit when the points open. The condenser also helps prevent ex- cessive burning of the breaker points. “di. The following section explaining what happens in the F-4 and F-6 magnetos is broken up into two parts. The first part covers the magnetic circuit in the magnetos, and the second covers’ the electric circuit in the magnetos. Each circuit depends upon the other for suc- cessful magneto operation and this rela- tion should be understood after reading the following. Magnetic Circuit in the International F-4 and F-6 Magnetos Lines of magnetic force will pass through some substances more readily than through others. When a piece of iron or steel is placed ina magnetic field, the lines of force are bent out of their natural path and pass’ through the iron. There will be more lines of force passing through the space occupied by the iron than when this space was oc- cupied by air only. This magne} Xe. prin- ciple of magnetic lines of force,: taking the path of least resistance, is utilized in the F-4 and F-6 magnetos. BLUE LAMIN O UNITS POLE PIECES ILLUST. 3–SIIOWS PATH OF MAGNETIC LINES OF FORCE THROUGH THE F-4 AND F-6 MAGNETOS. The magnetic action in the F-4 and F-6 magnetos can best be explained from the diagrammatic views shown in Illusts. 3 and 4. Running over the magneto proper is a permanent horseshoe magnet. This magnet contacts a north pole piece on one side anda south pole piece on the other. (A section of each magnet has been cut out to show more clearly the internal construction of the magneto.) Between these pole pieces turns a rotor with very little clearance for air space. The rotor consists of two pairs of soft steel laminated units. Each pair of units is placed at 90° to the other. Laminated units are mounted in place and magnetically insulated from each other by an aluminum die casting. Through the center of the rotor, also magnetically insulated from the laminated units, is a shaft. (Shaft is not shown in illustra- tions.) Directly over each pair of laminated rotor units is a laminated interpole. The two interpoles are connected by a coil core, around which is wound the primary and secondary coils. From previous explanation it must be remembered that magnetic l

File Type: pdf
File Size: 33 MB
Categories: magnetos