ERA Office: Monday – Friday 9:00-5:00 CST

275 W. BROWN ST, UNION, MO 63084

636-584-7400

office@electricalrebuilders.org

ERA Tech Helpline: 636-584-TECH (8324)

y Ai 4h 3 + ‘ the a Saat om ar , mini dine: ) mint tune: Ther . “-Seit-containea — No Batteries peeves ~ Model 3001-3002-3003-3004 | iol Pern ee ee mini tune ~ fe ee ie — — tune : r ce ee E 4 fa roe Ga 054 7 fe 706 ti, Sa Set %, Padbegoos:sas? ss i + All 2001, 3002, 3003, 2004. ae y ? IMPORTANT BEFORE YOU PLUG YOUR TESTER INTO A WALL OUTLET MAKE SURE THAT THE LINE CORD RECEPTACLE HAS THE GROUND PIN IN PLACE, DO NOT REMOVE THE GROUND PIN FROM THE RECEPTACLE SINE THIS WILL RESULT IN PROBLEMS WHEN TESTING FORD STARTERS. VOID EXTENSION CORDS IF POSSIBLE» ~ IF YOU USE AN EXTENSION CORD a SURE IT IS OF HEAVY DUTY MATERIALS, AND IS NOT LONGER ‘THAN FEET. WHEN HOOKING UP YOUR TESTER TO THE ACTUAL LINE VOLTAGE MAKE SURE THAT YOU HAVE AT LEAST A 15 AMP CIRCUIT BREAKER, WE PREFER A 20 AYP. TT 1S IMPORTANT THAT YOU DO NOT HAVE ANYTHING ON THE SAME LINE AS THE TESTER. ; | TURN YOUR VISE AROUND, MAKE SURE THAT THE BELT GUARD IS INA SECURE POSITION, IN SOME INSTANCES YOU WILL SEE SPECIAL FOOT NOTES. IF YOU DO NOT FOLLOW THESE SPECIAL NOTES YOU WILL HAVE PROBLEMS WITH ALTERANTORS, GENERATORS, AND STARTERS THAT COULD BE GOOD WORKING UNITS.” WE – pong sal YOU READ THE MANUAL WHEN TESTING ALTERNATORS, GENERATORS, SERVICE: IT IS NOT NECESSARY TO SHIP YOUR TEST BENCH» TO THE SERVIC CE. CENTER UNLESS THERE IS A SERIOUS PROBLEM NOTED. MINI TUNE IS HERE TO HELP YOU WITH ANY INSTRUCTION. HOWEVER, WE ASK FOR YOUR -CORPERATION BY GIVING US A CALL COLLECT TO MR. SERVICE AT: 707-763-7460 ade woeonnw fF WN ror ges mee Whe FE © 14, 15. 16. 17, 18. 19, ~ TABLE OF CONTENTS IMPORTANT NOTICE INFORMATION HINTS EXPLANATION OF TEST BENCH DESCRIPTION AND TECHNICAL DATA ACCESSORIES | OPERATION FIRST TEST (MECHANICAL) DELCOTRONS WITH INTERNAL REGULATOR SELF-EXCITING REGULATOR. TESTING CHRYSLER ISOLATED FIELD ALTERNATORS 24°VOLT TEST PROCEDURE GENERATOR TESTING STARTER TESTING SOLENOID TESTING STARTER CONNECTIONS . STARTER AMPERAGE DATA 3001-25 STARTER STRAP USAGE HOOK-UP AND TEST PROCEDURES QUICK REFERENCE CHARTS, ALTERNATORS, GENERATORS AND FOREIGN ALTERNATORS LEAD COLORS RED- § BATTERY TERMINAL LEAD R-F PLUG SEE GREEN AND YELLOW JOINING YELLOW- STATOR TERMINAL… RF MEANS RELAY FIELD PLUG. GREEN- FIELD TERMINAL GROUND- SEE GROUND ALIGATOR CLIP . . i NOTE MAKE SURE THE CABLE LEADS ARE ALWAYS. TIGHTLY CORRECTED YO THE CHORD IP IMPORTANT..NOTICE WE, STRONGLY,.RECOMMEND THAT, YOU FAMILIARIZE YOURSELF WITH THE: 3001 ALTERNATOR, GENERATOR, STARTER TEST~BENCH-BY -READING~THE INSTRUCTION MANUAL SUPPLIED WITH THE 3001. WE HAVE.RECEIVED NUMEROUS ~ COMPLAINTS ABOUT» THE OPERATION OF. THE UNIT. IF THE OPERATOR WOULD HAVE. TAKEN; THEs TIME. TO-READ THE -MAN- UAL, THESE COMPLAINTS WOULD NOT HAVE COME ABOUT, WE AGREE THAT FROM TIME TO TIME QUESTIONS DO COME UP WHERE ALL OF US ARE IN DOUBT. IN SUCH A CASE, PLEASE CALL THE FACTORY (COLLECT) OR, EVEN BETTER, MAIL US THE ALTERNATOR, GENERATOR OR STARTER AND WE WILL WRITE UP AN INDIVIDUAL TEST REPORT WHICH Wb THEN BENEFIT EVERYONE. IT SHOULD ALSO BE KNOWN TO YOU THAT OUR. CUSTOMER SERVICE IS AVAIL- ABLE ANYTIME: OFFICE HOURS |ARE FROM 8:00.A.M.°TO 4:00 P.M, CALIFORNIA TIME. ASK FOR.SERVICE ASSTSTANCE-AND WE°WELL ANSWER ANY QUESTIONS ON SERVICE PROBLEMS YOU ENCOUNTER, INFORMATION–HINTS:————»- My ; 1, CONNECT YOUR TEST’BENCH TO A GOOD GROUNDED OUTLET. WE RECOMMEND A 15 To 25 AMP CIRCUIT BREAKER. DO NOT USE AN EXTENSION CORD OR REMOVE THE GROUND PIN FROM THE PLUG WHICH GOES INTO THE RECEPTACLE. 2. TURN YOUR VISE AROUND SO ALL THREE HOLD-DOWN KNOBS PRESS – THE VISE DOWN SECURELY. THE REASON THE VISE IS BOLTED BACKWARDS > WITH ONLY TWO KNOBS HOLDING THE VISE IS TO PREVENT DAMAGE DURING SHIPPING, 3, ALIGN YOUR BELT WITH MOTOR/ALTERNATOR PULLEY. 4, WHEN OPERATING THE GENERATOR OR ALTERNATOR PORTION OF THE TEST BENCH, PLEASE KEEP YOUR BELT GUARD IN POSITION TO AVOID BODILY INJURY. THE BELT GUARD SHOULD ALWAYS BE IN POSITION BEFORE STARTING THE BENCH, 5. WHEN OPERATING YOUR STARTER, PLACE THE STARTER INTO THE VISE AND BOLT DOWN THE STARTER. AGAIN, PLACE THE BELT GUARD IN POSITION BEFORE OPERATING THE STARTER. NOTE: IF YOU FAIL TO DO THIS AS RECOMMENDED IN POINT 5, YOU MAY DAMAGE THE STARTER OR HURT YOURSELF, METER PANEL DESCRIPTION oie peal Main. Lead 7 : EXPLANATION LIGHT. 1 – GREEN IN COLOR, IS YOUR LOAD INDICATOR LIGHT AND COMES ON IF THE ALTERNATOR OR GENERATOR PRODUCES A CURRENT UNDER A FIXED LOAD, LIGHT 2 – GREEN IN COLOR, IS YOUR STATOR RELAY INDICATOR LIGHT AND ONLY WORKS. WHEN YOU HAVE AN ALTERNATOR WITH BUILT- IN STATOR, AND MADE THE CONNECTION PROPERLY, IGHT.3 = i LIGHT 4 – SWITCH 5 – SWETCH 6 — SWITCH.7– CLEAR IN COLOR, IS YOUR DIODE TRIO INDICATOR LIGHT WHICH COMES ON IMMEDIATELY WHEN YoU TURN THE TEST BENCH ON) NO ‘MATTER IF YOU HAVE’ A GENERATOR OR AN ALTERNATOR MOUNTED. THE LIGHT SHOULD GO OUT WHEN YOU PRESS THE LOAD SWITCH INDICATING ALTERNATORS: WITH INTERNAL~ REGU- S LATOR, ~ ALLO INTERNAL MOUNTED REGULATORS WORK UNDER THIS PRINCIPLE,° MAY. IT’ BE DOMESTIC’ OR FOREIGN. WHEN TESTING ALTERNATOR OR® GENERATOR WITHOUT REGULATORS, THIS LIGHT WILL STAY ON, RED IN COLOR, IS YOUR DEFECTIVE’ ALTERNATOR INDICATOR LIGHT AND COMES ON WHEN YOU HAVE A MAIN DIODE PROBLEM OR A STATOR IN°BALANCE ‘ PROBLEM, MEANING YOUR ALTERNATOR vPS DEFECTIVE. FLICKERING MEANS INTERFERENCE BUT DOES NOT MEAN ALTERNATOR “IS DEFECTIVE. | THE-RED LIGHT MUST BE ON BRIGHT RED BEFORE ALTERNATOR CAN BE FOUND DEFECTIVE INDICATES (ALTERNATOR OR GENERATOR TYPE. ‘PRESS TO DE- STRED POSITION, DEPENDING’ ON ‘WHAT YOU ‘WISH TO TEST. INDICATES A-GENERATOR TYPE’’SYSTEMS; B-GENERATOR TYPE SYSTEMS.) A=CIRCUIT) GENERATORS’ FIELD TIED TO ARMATURE, B-CIRCUIT GENERATORS FIELD CURRENT SUPPLIED WITH THE REGULATOR, AS; A- GENERAL, RULE) = GENERAL MOTORS, CHRYSLER AND AMERICAN MOTORS VEHICLES WITH GENERATORS, REFER TO “A” TYPE CIRCUIT, ON FORD VEHICLES WITH GENER~ ATORS) REFER TO. “B” CIRCUIT, NOTE: GENERALLY,’ AN’ “A” GENERATOR HAS ITS BATTERY TERMINAL ON: TOP” OF GENERATOR! CASE)” Ai “B” TYPE CIR- CUIT HAS THE} BATTERY TERMINAL ON THE REAR OF THE GENERATOR HOUSING. es INDICATES POSITIVEOOR NEGATIVE “GROUND, MOST SYSTEMS ARE NEGATIVE. CONSULT YOUR MANUAL FOR FURTHER SPECI- FICATIONS,

File Type: pdf
File Size: 17 MB
Categories: manuals