FULL OUTPUT ~ GENERATOR – ALTERNATOR – STARTER TESTBENCH MODEL 7001 Operation Instructions #700186 io COM™mM OWN FW Rh F ae ae Nr oO FULL OUTPUT TESTBENCH 3.5 HP – 230V – 50/60 HZ VOLTMETER AMMETER LOAD LIGHT STATOR RELAY LIGHT DIODE TRIO LIGHT DEFECTIVE ALTERNATOR LIGHT LINE FUSE IGNITION LIGHT DELCOTRON CABLE MAIN CONNECTION & HARNESS LOAD INDICATOR LIGHT LOAD KNOB STARTER SWITCH MOTOR SWITCH ALTERNATOR WITH INTERNAL REGULATOR SWITCH 6V OR 12vV SYSTEMS POSITIVE OR NEGATIVE SYSTEMS A OR B SYSTEMS ALTERNATOR WITH REGULATOR OR GENERATOR MODE SWITCH HOLD DOWN VISE REGULATOR FUSE OSCILLOSCOPE MODEL 1405 CONNECTION : (2) FEATURES 1, VOLTMETER THE O-18V SCALE VOLTMETER, IS USED TO MONITOR THE ALTERNATOR OR GENERATOR’S OUTPUT VOLTAGE WITH OR WITHOUT A LOAD, 2, AMMETER THE AMMETER HAS TWO SCALES. THE O-120 SCALE IS TO MONITOR ALTERNATOR AND GENERATOR‘S LOAD AMPERAGE, THE O-200 AMPS SCALE IS TO MONITOR THE STARTER‘’S FREE SPIN AMPERAGE. NOTE: BOTH VOLTMETER AND AMMETER MUST BE MONITORED SIMULTA- NEOUSLY, WHEN LOAD TESTING AN ALTERNATOR OR A GENERATOR, 3, LOAD LIGHT (GREEN) THIS IS THE LOAD INDICATOR LIGHT AND IT COMES ON IMMEDIATELY UPON STARTING THE DRIVE MOTOR, 4, STATOR: RELAY LIGHT (GREEN) THIS IS THE STATOR OUTPUT INDICATOR LIGHT, AND ONLY WORKS WHEN TESTING AN ALTERNATOR STATOR TERMINAL WHICH IS CONNECTED TO THE STATOR WIRE OF THE TESTBENCH, 5, DIODE TRIO LIGHT (CLEAR) THE DIODE TRIO LIGHT INDICATES THE CONDITION OF THE DIODE TRIO DEVICE IN A DELCOTRON ALTERNATOR AND SHOULD REMAIN OFF WHEN TESTING A GOOD DELCOTRON ALTERNATOR AND COMES ON WHEN ONE OR MORE OF THE DIODES IN THE DEVICE ARE SHORTED OR OPEN. HOWEVER, THIS LIGHT WILL REMAIN “ON”, WHEN TESTING GENERATORS AND ALTER- NATORS WITH EXTERNAL REGULATORS, 6, DEFECTIVE ALTERNATOR LIGHT (RED) THIS IS THE RIPPLE OUTPUT INDICATOR LIGHT THAT COMES ON WHEN YOU HAVE AN ALTERNATOR IMBALANCE PROBLEM, SUCH AS MAIN DIODE, STATOR IMBALANCE, ETC. THIS TYPE OF FAULT USUALLY RESULTS IN A DROP IN THE ALTERNATOR OUTPUT VOLTAGE AND AMPERAGE. IF THE OUTPUT VOLTAGE AND AMPERAGE IS NORMAL, BUT THE LIGHT COMES ON DIM AND FLICKERS, THE ALTERNATOR SHOULD NOT BE REJECTED, THIS EFFECT IS CAUSED BY THE MECHANICAL REGULATOR IN THE BENCH’S ELECTRONIC SYSTEM, 7, LINE FUSE 3/4 AMP LINE PROTECTION FUSE, 8, IGNITION LIGHT (RED) THIS IS THE SOLENOID COIL WINDING CONTINUITY INDICATOR /GHT, THIS LIGHT INDICATES WHEN THE IGNITION TESTLEAD IS CONNECTED TO THE STARTER RELAY CONTACT, -OUNDED 10, nie 12, 13, 14, (3) DELCOTRON CABLE THIS CABLE HAS A STANDARD TWO TERMINAL DELCOTRON PLUG AT THE END, THIS IS PLUGGED INTO A DELCOTRON TYPE ALTERNATOR UNDER TEST, MAIN CONNECTION AND HARNESS THE BLACK HEAVY DUTY WIRE AND CLAMP USED AS GROUND (-) CONNECTION, IS COMMON TO AN ALTERNATOR, GENERATOR OR STARTER TEST. THE RED HEAVY DUTY CLAMP CAN BE CONNECTED TO THE TESTBENCH ALTERNATOR/ GENERATOR WING NUT TERMINAL, WHEN TESTING ALTERNATORS OR GENERATORS, OR IT CAN BE CONNECTED TO THE STARTER WING NUT TERMINAL FOR STARTER FREE SPIN TESTING. THE FIELD HAS A GREEN ALLIGATOR CLIP, THE STATOR HAS A YELLOW ALLIGATOR CLIP, THE STATOR AND FIELD ARE ALSO TERMINATED INTO THE R-F PLUG. THIS PLUG IS USED ON EARLIER DELCO ALTERNATORS AND LABELED “RELAY TO FIELD PLUG’. LOAD INDICATOR LIGHT THIS LIGHT IS LOCATED ABOVE THE LOAD KNOB AND COMES ON, WHEN THE CARBON PILE IS ENGAGED, LOAD KNOB A LOAD CAN BE PUT ON THE UNIT BY TURNING THE CARBON PILE KNOB CLOCKWISE SLOWLY TO INCREASE THE LOAD. A MAXIMUM OF 120 AMPS MAY BE INTRODUCED, WHEN TESTING HEAVY DUTY 12V ALTERNATORS, CAUTION: WHEN INCREASING THE LOAD, DO NOT LET THE VOLTAGE DROP BELOW 13v ON A 12V ALTERNATOR OR GENERATOR, OR BELOW 6.5vV ON A 6V UNIT. AS REGULATION CIRCUIT MAY CUT OFF THE FIELD EX- CITATION. IF THIS OCCURS, REMOVE THE CARBON PILE LOAD BY TURNING THE KNOB, COUNTER-CLOCKWISE AND REACTIVATING THE REGULATOR, STARTER SWITCH MOMENTARY PUSH-ON, THAT TURNS THE STARTER MODULE ON, LET THE METER NEEDLE SWING OUT, THEN STABILIZE, TAKE YOUR READING AND RELEASE THE SWITCH. ALL OF THIS MUST BE DONE IN A MATTER OF SECONDS. READ YOUR STARTER INSTRUCTIONS FOR FURTHER DETAILS, MOTOR SWITCH THIS IS A THREE POSITION SWITCH. TIIRN CLOCKWISE OR COUNTER CLOCK WISE POSITION, WHICHEVER, IS RECOMMENDED BY THE MANUFACTURER. CENTER POSITION IS “OFF”, (4) 15; 16, L7., 18, 19, 20, 21, ALTERNATOR/GENERATOR ~ ALTERNATOR WITH INTERNAL REGULATOR SWITCH THIS SWITCH IS SET IN ONE OF THE TWO POSITIONS THAT CORRESPONDS WITH THE UNIT UNDER TEST. 6V OR 12V SYSTEMS THIS SWITCH IS SET TO CORRESPOND WITH THE VOLTAGE OF THE UNIT UNDER TEST, POSITIVE OR NEGATIVE SYSTEMS SET THIS SWITCH TO CORRESPOND WITH THE UNIT UNDER TEST. “NEGATIVE” FOR THE NEGATIVE GROUND SYSTEM, “POSITIVE” FOR THE POSITIVE GROUND SYSTEM, A OR B SYSTEMS “na” CIRCUIT GENERATORS ARE THOSE WHERE THE FIELD CURRENT IS SUPPLIED FROM THE ARMATURE TERMINAL, INSIDE THE GENERATOR AND THE FIELD COILS ARE GROUNDED THROUGH THE REGULATOR. “BY CIRCUIT GENERATORS ARE THOSE WHERE THE FIELD CURRENT IS SUPPLIED FROM THE REGULATOR AND THE FIELD COILS ARE GROUNDED INSIDE THE GENERATOR, “a” CIRCUIT ALTERNATORS ARE THOSE WHERE THE FIELD CURRENT IS SUPPLIED FROM THE BATTERY TERMINAL INSIDE THE ALTERNATOR AND THE ROTOR (FIELD COIL), IS GROUNDED THROUGH THE INTERNAL REGULATO “BY” CIRCUIT ALTERNATORS ARE THOSE WHERE THE FIELD CURRENT IS SUPPLIED FROM THE EXTERNAL REGULATOR AND THE ROTOR (FIELD COIL) 1S GROUNDED INSIDE THE ALTERNATOR, ISOLATED FIELD ALTERNATORS (CHRYSLER 2 FIELD TERMINALS) ARE ALTERNATORS WHERE THE FIELD CURRENT IS SUPPLIED FROM THE IGNITION RESISTOR AND THE ROTOR (FIELD COIL) IS GROUNDED THROUGH THE EXTERNAL ELECTRONIC REGULATOR. ALTERNATOR WITH REGULATOR OR GENERATOR MODE SWITCH SET THIS SWITCH TO CORRESPOND WITH THE UNIT UNDER TEST, HOLD DOWN VISE USE THIS VISE TO CLAMP DOWN THE ALTERNATOR, GENERATOR OR STARTER, THEN PROPERLY ALIGN THE COMPONENT ALTERNATOR, GENERATOR OR STARTER, TO AVOID THE ACCIDENTAL SLIPPING OF THE DRIVE BELT, TURN THE PULLEY BY HAND FIRST, TO MAKE SURE THE BELT IS ON THE PULLEY TRACK, pepe yc TENSION MAY BE APPLIED BY ENGAGING THE ALTERNATOR TENSION RACKET. REGULATOR FUSE REGULATOR CONTACT PROTECTION,