ERA Office: Monday – Friday 9:00-5:00 CST

275 W. BROWN ST, UNION, MO 63084

636-584-7400

office@electricalrebuilders.org

ERA Tech Helpline: 636-584-TECH (8324)

Printed in U.S.A. @, prestolite.___MKS Page 1 of 3 INFORMATION Issued 10/16/86 VOLTAGE 12 ROTATION Reversible BRUSHES 4 POLES 4 VENTILATED SEE TABULATION FRAME DIAMETER 6-5/8″ LUBRICATION None required. Prelubricated and sealed bal] FIELD RESISTAN ARMATURE TEST COMMUTATOR CE (77°) BRUSH REPLACEMENT SPRING TENSION TEST CONNECTIONS (77°F) CWDE bearings used at both ends of motor. -0031 to .0036 ohms measured between terminals S-1 and 8-2 or $8-3 and S-4, These armatures have standard winding conn- ections and can be tested on a growler for shorted windings. Minimum diameter 2.875″. Replace armature when commutator has worn to this dimension. Replace brushes when they have worn to a length of 9/16″ or less. 30 to 36 ounces with new brushes. Measure with a spring scale hooked under the brush spring at the brush. Pull the scale on a line opposite the line of force exerted by the brush spring and take the reading just as the spring leaves the brush. TEST #1 CCWDE Cannect S-1 to battery positive Connect S-1 to battery positive Connect S-2 to Connect A-2 to CWDE Connect A-1 to A-1 Connect 5-2 to A-2 battery negative Connect A-1 to battery negative Connect A-2 to S-2 Connect S-1 to TEST #2 CCWDE battery positive Connect A-1 to battery positive – Connect A-2 to S-1 battery negative Connect S-2 to battery negative File in the 1-600 SERVICE MANUAL ==> MKS ~- IN prestolite. Page 2 of 3 SERVICE Issued 10/16/86 INFORMATION TEST #3 HIGH SPEED CWDE CCWDE Connect S-1 to battery positive Connect $-1 to battery positive Connect S-2 to A-1 Connect 5-2 to A-2 Connect A-2 to battery negative Connect A-1 to battery negative CWDE Connect A-2 to battery positive Connect A-1 to $-3 Connect S-2 to 5-4 Connect 5-1 to battery negative TEST SPECIFICATIONS (77°F) LOW SPEED CCWDE Connect A-1 to battery positive Connect A-2 to $-3 Connect 5-2 to $-4 Connect S-1 to battery negative USE LOW SPEED CONNECTIONS FOR TWO SPEED MOTORS DURING NO LOAD TEST. WSE HIGH SPEED CONNECTIONS FOR LIGHT LOAD TEST. Terminal Maximum Torque Voltage Amperes RPM Ft. Lbs. No Load Test 12 28 3800 Min. – 0 – Light Load Test 11.28 100 2400-2680 Z TEST INTERNAL UNIT VENTILATED CONNECTIONS WIRING MKS-4001 YES #3 Figure l MKS-4002 NO #1 Figure 2 MKS -4003 NO #1 Figure 2 MKS-4004 NO #2 Figure 3 MKS -4005 YES #3 Figure 1 prestolte— SERVICE _ Traction Motor Page 3 of 3 INFORMATION Issued 10/16/86 VIEWED FROM COMMUTATOR.END VIEWED FROM COMMUTATOR END FIG. 1 FIG. 2 VIEWED FROM COMMUTATOR END FIG. 3 File in the ‘ZAN CeDVice AARILIAS ———_> TRACTION MOTND ¢CertiIc

File Type: pdf
File Size: 2 MB
Categories: prestolite