©, prestoalite, ¥°. = , SERVICE Trae bah INFORMATION | oe VOLTAGE 24 ROTATION Reversible BRUSHES 4 POLES 4 VENTILATED Yes FRAME DIAMETER 5-9/16″ LUBRICATION D.E. bearing prelubricated and sealed. C.E. bearing sealed one side only. At overhaul fill reservoir in C.E. head 1/2 full with a good grade bal] bearing Jubricant. ARMATURE TEST These armatures have standard winding connections and can be tested on a growler using a metal strip or hacksaw blade to locate shorted windings. COMMUTATOR Minimum. diameter 1.60″. Replace armature – when commutator has worn to this dimension. BRUSH REPLACEMENT ‘ Replace brushes: when they. have. worn to a length of 1/2″ or less. Lee } SPRING TENSION 20-22. ounces with new brushes measure with a spring scale hooked under the brush spring at the brush. Pull the scale on a line opposite the line of force exerted by the brush spring and take the reading just as the spring leaves the brush. BRUSH ADJUSTMENT These motors have an adjustable brush card. The brush card should be adjusted to neutral, or with hold down screws in the center of the adjusting slots. TEST SPECIFICATIONS (77°F /25°C} Terminal Max imum Torque Voltage Amperes RPM Ft. Lbs. No Load Test 26.0 10 2100 Min. 0 Light Load Test 26.0 35 1800 Min. 2 File in the prinied in USA L600 SERVICE MANUAL ==> __ Traction Motor O, prestolite. SERVICE —Page 2? of 2 1/15182 INFORMATION UNIT MPL-4001 MPL-4002 VIEWED FROM COMMUTATOR ENO WX prestolte._â„¢? SERVICE Pump Motor _ Page 1 of J) INFORMATION Issued 3/16/78 VOLTAGE 24 ROTATION Reversible BRUSHES 4 POLES 4 VENTILATED Yes FRAME DIAMETER 5-1/2″ BEARINGS Ball bearings used at both ends. LUBRICATION Fill bearing cups half full with Chevron SRI #2 or equivalent before assembly. Assemble sealed side of bearings inward towards armature. BRUSH REPLACEMENT The brushes must be replaced when they have worn to a length of 3/8″ or less. SPRING TENSION 22 to 30 ounces with new brushes. Measure with a spring scale hooked under the brush spring at the brush. Pull the scale on a line opposite the line of force exerted by the brush spring and take the reading just as the spring leaves the brush, TEST CONNECTIONS CCWDE CWDE Connect battery positive to – terminal Connect battery positive to + terminal Connect battery negative to + terminal Connect battery negative to – terminal TEST SPECIFICATIONS (779F/250C) Terminal Maximum Torque Voltage Amperes RPM Ft. Lbs. No Load Test 26 6 2200 -O- Stall Torque Test 26 210 – 0 – 16.5 Unit Special Notes MPL-400] See Note Note – Internal wiring diagram does not illustrate circuit breaker. VEO FROM COMMUTATOR ENO File in the oe me Be RTA =>, Pump Motor Section