ss pX FILE IN THE PTestaswrte SERVICE MANUAL GENERATOR SECTION PAGE 1. (Issued 3-16-78) UNIVERSAL GENERATOR TEST SPECIFICATIONS Generator Sales Number P45-721 – P45-722 – P45-723 – P45-724 – P45-725 – P45-726 – P45-727 – P45-761 – P45-762 – P45-763 – P45-764 – P45-765 – Printed in U.S.A. See Specification Number -§-3 S-| SQ Prestolite SERVICE MANUAL PAGE 2, VOLTS t2 VENTILATED Yes ROTATION CWDE POLES 2 BRUSHES 2 CONTROL Vibrating Current Voltage Regulator BRUSH SPRING TENSION 18 to 36 ounces with new brushes. Tension is measured by using an adaptor and hooking it under the brush arm as near to the brush as possible. Take reading just as the arm leaves the brush, LUBRICATION Add oil to oiler at regular chassis lubrication, or every 3,900 miles, GROUND POLARITY Negative FIELD COIL DRAW (70°F) 1,2 to 1,3 amperes at 10,0 volts, MOTORING DRAW (70°F) 3.4 to 3.9 amperes at 10.0 volts. NOTE: For figure 1, have field terminal grounded to frame. For figure 2, have field terminal connected to arma- ture terminal. OUTPUT TEST 15.0 volts, 25.0 amperes, 2100-2200 RPM 15.0 volts, 30.0 amperes, 2250-2375 RPM 15,0 volts, 35.0 amperes, 2250-2650 RPM Do not operate at high output for any length of time without the ventilating fan. To do so may result in burned armature and fields. Rated Internal Unit Output Wiring a a P45-721 30 Amps Fig, 1 P45-722 30-35 Amps Fig. 2 P45-723 30-35 Amps Fig. 2 P45-724 30 Amps Fig. P45-725 30 Amps Fig. 1 FIELD ARMATURE FIELD ARMATURE TERMINAL TERMINAL TERMINAL J TERMINAL GROUNDED INSUL ATED GROUNDED BRUSH INSULATEG BRUSH BRUSH BRUSH VIEWED FROM COMMUTATOR END VIEWED FROM COMMUTATOR ENO Figure 1. Figure 2, Printed in U.S.A. FILE IN â„¢ Ss _ 2 ©, Prestolite siRNick MANval GENERATOR SECTION PAGE 3 (Issued 3-16-78) VOLTS 12 VENTILATED Yes ROTATION CWDE POLES 2 BRUSHES 2 CONTROL Vibrating Current Voltage Regulator BRUSH SPRING TENSION 18 to 36 ounces with new brushes, Tension is measured by using an adaptor and hooking it under the brush arm as near to the brush as possible. Take reading just as the arm leaves the brush, LUBRICATION Add oil to oiler at regular chassis lubrication, or every 5,000 miles, GROUND POLARITY Negative FIELD COIL DRAW (70°F) 1.2 to 1.3 amperes at 10. 0 volts. MOTORING DRAW (70°F) 2.9 maximum amperes at 10,0 volts. NOTE: Have field terminal grounded to frame, OUTPUT TEST 15.0 volts, 25.0 amperes at 2800 minimum RPM (hat) Do not operate at high output for any length of time without the ventilating fan. To do so may result in burned armature and fields. Rated Internal Unit Out put Wiring a lll P45-726 25-30 Amps, Fig. 1 P45-727 25-30 Amps. Fig, 1 FIELD ARMATURE TERMINAL GROUNDED BRUSH INSULATED BRUSH VIEWED FROM COMMUTATOR END Figure 1, Printed in U.S.A.

File Type: pdf
File Size: 3 MB
Categories: prestolite