ERA Office: Monday – Friday 9:00-5:00 CST

275 W. BROWN ST, UNION, MO 63084

636-584-7400

office@electricalrebuilders.org

ERA Tech Helpline: 636-584-TECH (8324)

This electronic box is usually to the left of Stator Mount Box Rotating Element STATOR QUALIFIER THEORY The tester is our shorted coil detector system rotating within the stator. Therefore all coils of a stator are scanned at 800 times per minute. MOTOR OSCILLATOR POWER SLIP RINGS OSCILLATOR ROTATING DEVICE 4 Theory (con’t) Top View ground to metal ring outside coils 3 output leads of typical stator set rate meter counter balanced rotating device with adjustable diameter which contains the oscillating coil represents all three coil windings 3 test leads N phase select switch /to select any two leads at a time oo electronics COMPONENTS OF SYSTEM BLUE BOX #1: Contains the stator support and rotating device. The rotating device can be adjusted to fit inside stators. The stators will be positioned by a plastic sleeve inside of stator and held at correct height by supports around outside of laminations. The operating motor is mounted in the bottom of the box and is operated by a run switch. BLUE BOX #2: Contains the eléctronics and meters. A scope connects to #2 blue box. PLASTIC SLEEVES: These are a two part device for centering the stators over the rotating element. We recommend reaching through the tube and knocking off the lid prior to installing the unit on the machine as there is no good means for its removal after it’s installed. Once it is installed, __._-‘* the rotating element set and operating freely, then the cap can be reinserted for protection. BLUE BOX #2 FACE Core Rate ©) Set | OO ©») O . Centering Input type OO Scope _._. __ BLUE BOX-#2-CONTENTS-—~-—- > Set-Rate Switch: Selects which circuit will be displayed on left meter. Set-Rate Meter: Is used to set the level and then to rate the stator. Set-Pot (Dial): Set the level . for a typical stator so that fault circuit will operate correctly, . Fault Meter: Indicates fault of some type in stator under test. Type Switch (Dial): Six positions to set the circuit to operate with different stators. Balance & Centering Pot (Dial): Sets the rate meter to mid position (with a good medium stator on the machine). Input Jacks are to connect to output of Box #1. Scope Jacks connect to the scope. TO CALIBRATE SET UP This procedure is only necessary if plastic centering holder support plate is moved or if one is testing odd stators without plastic support. to test stators, it is necessary to have them as close to centered as possible. So we start by centering the stator holding fixture. To hold the stator concentric with rotating element. The centering is done with a good stator of medium output of the type to be tested. When first centering a stator holding fixture, one can get an approximate center by rotating the rotating element by hand and observing clearance. The usual clearance while testing will be to have the rotating devise about 1/8” from stator laminations. The final centering is done with rotating devise being driven by the motor and observing scope pattern. Place the set knob at about 5 for this setting procedure. Hook up test leads as shown in electric hook up figure (page 5). Scope picture of properly centered stator A WY 1, Scope picture of stator not centered By shifting holding fixture the good pattern can be obtained. When good picture is obtained the holding fixture is tightened and is ready to use. With the mechanical set up complete, it is time to set up the electronic box. We have a good stator ofm medium output setting in the fixture and hooked ui so we are ready to Proceed. Place set-rate switch in set position and with tester + rotating, turn set knob until left meter is at set mark on meter face. Place type switch to correct position for type of stator being tested. (We hope 6 positions will be enough on type knob). Place set-rate switch to rate position. With motor running, turn centering-balance pot knob so meter reads medium (we are using a medium stator for test). ELECTRICAL HOOK UP Represents all 3 windings Steel Laminations 3 leads 3 phase leads Ground Jack O © Output to Blue Box #2 Three Jacks Oo OQ. o Each switch position will test a different combination of windings POWER AND MOUNTING Plug both AC plugs into good quality 110 AC, 3-prong outlets. Do not operate at end of long drop cord, as this can have a temporary voltage drop each time the motor starts. For safety purposes, it will be best to have the rotating element box below head level. Do not turn the rotating element on without the plastic cover in place. This tester uses the ground green/yellow wire of the electrical plugs to tie the two chassis together and prevent noise in the stator signal between the chassis. Blue Box #2 Scope Blue Box #1 Signal Lead . | STATOR SUPPORT SYSTEM Different plastic centering pieces will be furnished to hold 12 si, 27 si and HI Amp Ford. Others will be available. Plastie centering clamps will be retained by 2 hold down clamps. After removing these 2 clamps one can change the plastic centering piece for different stators. Whenever different stators are tested it will be necessary to change the plastic piece, reset the width of the rotating device and reset the support slides, The plastic piece will center the stator and the support slides will only hold the stator at the correct height. Plastic centering piece , Hold down clamps for plastic centering piece eae Oversize holes so that 8×12 x piece can be moved to center plastic centering piece. This plate will be set at factory and Should not need to be moved.

File Type: pdf
File Size: 13 MB
Categories: manuals