Revision #1, January 15, 1945 — Replaces Original SECTION SERVICE INSTRUCTIONS FOR INDEX Breaker Box . Breaker Points Cam . Coil . Condenser Cover Distributor Arm Distributor Cap. Drive Cup Drive Cup, Adjustable Drive Spring . Driven Flange Dust Cover End Plate Gear Housing Impulse Coupling Impulse Coupling Lock-nut Lag Angle Adjustment Main Housing Oiling System Parts Rotor Stop Devices Trip Arm. MODEL A MODEL A WICO MAGNETO > wo © WHO NH WW NY WD ~ MODEL A WICO MAGNETO Page A WICO SERVICE MANUAL DISTRIBUTOR CAP AND DISTRIBUTOR ARM SINGLE CYLINDER MODEL On single cylinder models neither distributor cap nor distributor arm are used as the high tension current is taken directly from the secondary terminal of the coil through the outlet in the cover of the magneto. The breaker compartment is covered by breaker cover 2074 which is held in place by 2 breaker box cover clips, X2075. To replace an old style breaker box cover, X1546, which has the clip on the cover, use the new cover 2074 and gasket 2072 and install two X2075 breaker box clips to the housing. R CYLINDER MODEL On R cylinder magnetos, which are two cylinder magnetos with the spark occuring every 180° of the magneto drive shaft rotation no distributor gears are used. The distributor cap is removed by wedging out the two clips which hold it in place. TWO AND FOUR CYLINDER MODELS On two and four cylinder magnetos the distributor cap is held to the gear housing by two spring clips and it is necessary to wedge these out with a screw driver before the cap can be removed. The distributor arm is fastened to the gear housing and may be removed by pulling off the shaft. For information regarding the removal of the gear housing see below. GEAR HOUSING After the distributor cap has been removed as men- tioned above, gear housing may be taken off by wedging out with a screw driver the two spring clips X1503. When replacing the gear housing make certain that the key in the gear shaft of the housing lines up with the slot in the rotor shaft of the magneto and that the gear hous- ing gasket is in place between the housing and the cover. The oil plug, 16-449, at the bottom of the gear housing should be removed and a small amount of SAE 90 oil should be applied. As shown in the service parts section of this manual the gear housing is supplied without distributor arm as X5999. BREAKER POINTS The breaker points should be adjusted to .015” when fully opened. Adjustment is made by shifting the fixed contact, 1196, by means of the smail eccentric screw. After adjustment, tighten the fixed contact screw, M-31X. The points should be free from foreign matter. Lac- quer thinner is an ideal cleaner for this purpose. Use Page A SERVICE INSTRUCTIONS Wico tool X5449 to adjust the alignment so that both surfaces of both contacts meet squarely. To remove the breaker arm, X1408, take out the breaker arm clamp screw, 16-738, lock washer, M- 55XA, clamp washer, 1207, and breaker arm spring terminal screw, 16-738, and lock washer, 2573. Next pull the breaker arm and the breaker arm spacer, 1418, off the pivot. When replacing make certain thet the leads from the coil and stop device are in place under the breaker arm spring terminal screw. To remove the fixed contact 1196 the breaker arm must first be removed as outlined above. Then take off the spacing washer, 1197, remove the clamp screw M-31X, lock washer M-55XA, and washer IXA-356, after which the fixed contact may be pulled off the breaker arm pivot. IF the points need replacing it is recommended that both the fixed contact and the breaker arm be repla¢ed at the same time. After reassembling the points should be adjusted as described in the beginning of this section. CONDENSER The condenser, X1413, should have a capacity , of 16-.18 microfarads. If the condenser when tested shows to be below capacity it should be replaced. To remove the condenser, X1413, disconnect the ground and coil leads by removing the breaker arm spring clamp screw, 16-738, and washer. After re- moving the two condenser screws, 1383, and lock washers, M-90X, the condenser may be removed by sliding it slightly away from the breaker arm pivot and pulling it upward. In replacing the condenser make certain that the condenser case gasket, 1533, is in place and that the coil and ground lead is firmly fastened. CAM The breaker cam may be pulled off the rotor alter re- moving cam screw, M-31X, lock plate, 1381, and lock washer, M-55XA. The Part numbers for the various cams are given in the service parts section of the manual together with il- lustrations for identifying them. COVER The cover may be removed by loosening the four screws, one in each corner of the cover, until they are free. It is not necessary to completely remove the screws from the cover. If the cover seems to stick it may be loosened by slightly tapping with the palm of the hand. When replacing the cover make certain that the gasket, 1385, is in place.